Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 45

INSTALLATION

Fix the stirrup G to the wall.
Insert the crown A in the driving wheel B of the limit switch
(fig.1).
Insert the pulley C on the pivot of the motor D (fig.1).
Insert the copper pin F on the pulley C.
Insert completely the motor in the roll-tube (fig.2).
Fix the roll-tube to the driving wheel with m 4 x10 screw (fig.2).
DESCRIPTION
This opening system is made of a tubular motor with built-in
control unit with the following characteristics:
It is provided with a 434.15 MHz super-heterodyne radio
receiver.
Up to 30 different channel can be stored on each central unit.
It is driven by means of transmitters PROTEO, DUO, ARTEMIS
and ADLER.
It is possible to drive the rolling shutter also by mean of an
external push-button (type: Normally Open, each series or
model).
The programming phase can be effected via radio or by means
of an external switch.
Obstacle detection: if during the closing phase of the rolling
shutter an obstacle is detected, the device opens the rolling
shutter completely.
FUNCTIONING WITH EXTERNAL WIRED
SWITCH
Pressing the external wired switch, the control unit has the
following functioning logic:
a
a
OPENS
STOPS
CLOSES
FUNCTIONING WITH TRANSMITTERS
At each push button pressure, the functioning logic is the
following.
a
UP:
OPENS
OPENS
a
STOP:
STOPS
STOPS
a
DOWN:
CLOSES
CLOSES
WORKING TIME OF MOTOR
The control unit stops the motor movement after 5 minutes: in
case of limit switches malfunction this "time out" avoids the
motor overheating.
a
a
STOPS
OPENS ...
a
OPENS
a
STOPS
a
CLOSES
TRANSMITTERS OF THE RANGE
PROTEO / DUO
Using a transmitter of the range PROTEO / DUO it is possible
changing the functions of the control unit controlling the tubular
motor.
The transmitter is equipped with a 10 switches dip-switch thanks
to which it is possible to change the desired functions: set on ON
the switch corresponding to the function required and follow
carefully the dedicated procedure.
WARNING: all the other switches have to be set on OFF
SWITCH
FUNCTION
1
NOT USED
2
Storage of transmitters
3
Deletion of all the stored transmitters
4
Programming of opening limit switch
5
Programming of closing limit switch (closed louver
blades)
6
Programming of opening position of adjustable
louver blades
7-8-9-10
NOT USED
- 16 -
DIP-SWITCHES
PROG

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Lex-rfe50-230v

Inhaltsverzeichnis