Herunterladen Inhalt Inhalt Diese Seite drucken

Main Structure; Installation - V2 WISANT-Serie Bedienungsanleitung

Elektromechanischer getriebemotor 230v/400v für industrielle sektionaltore bis zu 35m
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 43

MAIN STRUCTURE

Reducer casing

INSTALLATION

2nd spacer ring and screw
• Screw the wall bracket (L-shaped iron fitting) onto the wall with expansion bolt.
You may install the wall bracket to left side or right side of operator.
• Slot the 1st spacer ring onto the door shaft.
• Slot the door operator onto the door shaft (ensure correct position of the key) and screw onto the wall bracket.
• Slot the 2nd spacer ring onto the door shaft and push it against the operator, ensuring that the chain hangs vertically
• Press the 1st spacer ring against the operator and fix both rings.
Key
Expansion bolt
Cover
1st spacer ring
Bolt M10
12
Waterproof adapter
Motor
Hand chain components
Adjustable knob
Wall bracket
Door shaft

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Wisant 19-230vWisant 35-400v

Inhaltsverzeichnis