distance; High sensitivity with 8m, it fits for large room.
Time-Delay is added continually: When it receives the second induction signals after the first induction,
it will compute time once more on the basic of the first time-delay rest.
Time–Delay is adjustable. It can be set according to the consumer's desire. The minimum time is
10sec±3sec. The maximum is 12min±1min.
NOTE: the high-frequency output of this sensor is
th
<10Mw- that is just one 100
of the transmission power of
a mobile phone or the output of a microwave oven.
INSTALLATIION: (see the diagram)
Switch off the power.
Fix the bottom on the selected position with the inflated screw through the
screw holes in the side of the sensor.
Connecting the power and the load to sensor as per the connection-wire
sketch diagram.
Switch on the power and test it
CONNECTION-WIER SKETCH DIAGRAM
TEST:
Turn the LUX knob clockwise on the maximum (sun), turn the TIME
knob anti-clockwise on the minimum, turn the SENS knob clockwise
on the middle.
When you switch on the power, the controlled load and indication
lamp are both not working. Preheat 30 seconds later, the load and the indicator lamp are turned on
synchronization, in the absence of no inductor signals, the load should be stopped working within
5-30sec, the indicator lamp is turned off.
After the first sensor is out, 5-10sec later, the sensor could be worked again, and the load should work.
When there is no inductor signals in the indicator lamp, the load should be stopped working within
5-15sec.
Turn LUX knob anti-clockwise on the minimum. If it is adjusted in the less than 3LUX, the inductor load
should not work after load stop working. under no induction signal condition, the load should stop
working within 5-15sec.
Note: when testing in daylight, please turn LUX knob to
could not work!
: : : :
NOTES
Electrician or experienced human can install it.
The unrest objects can't be regarded the installation basis-face.
In front of the detection window there shouldn't be hinder or unrest objects effecting detection.
Avoid installing it near air temperature alteration zones for example: air condition, central heating, etc.
For your safety. Please don't open the case if you find hitch after installation.
In order to avoid the unexpected damage of product, please add a safe device of 6A when installing
infrared sensor, for example, fuse, safe tube etc.
SOME PROBLEM AND SOLVED WAY
The load don't work:
a. Check the power and the load.
b. Whether the indicator light is turned on after sensing? If yes, please check load.
c. If the indicator light does not turn on after sensing, please check if the working light
corresponds to the ambient light.
d. Please check if the working voltage corresponds to the power source.
The sensitivity is poor:
a. Please check if in front of the detection window there are hinder that effect to receive the
signals.
b. Please check the ambient temperature.
c. Please check if the signals source is in the detection fields.
d. Please check the installation height.
The sensor can't shut automatically the load:
a. If there are continual signals in the detection fields.
b. If the time delay is set to the longest.
c. If the power correspond to the instruction.
d. If the air temperature change near the sensor, air condition or central heating etc.
Šis gaminys – tai naujas energiją taupantis jungiklis, kuriame įdiegtas mikrobangų jutiklis ir aukšto dažnio
elektromagnetinių bangų (5,8 GHz) integrinis grandynas. Jame
LT
dera automatika, patogumas, saugumas, energijos taupymas ir
praktiškumas. Detektoriai stebi platų apžvalgos lauką. Jutiklis
veikia fiksuodamas žmogaus judesius. Į apžvalgos lauką įžengus žmogui, ju-
tiklis gali iškart pradėti veikti ir automatiškai nustatyti, ar tuo metu diena, ar
(SUN) position, otherwise the sensor lamp

Werbung

loading