Fixture ID
Service PIN
The password for this function is „050".
RDM
With this function you can call up various submenus via RDM.
This device is RDM ready. RDM stands for "Remote Device Management" and makes remote control of
devices connected to the DMX-bus possible. ANSI E1.20-2006 by ESTA specifies the RDM standard as an
extension of the DMX512 protocol.
Manual settings like adjusting the DMX starting address are no longer needed. This is especially useful when
the device is installed in a remote area.
RDM is integrated n the DMX-protocol without influencing the connections. The RDM-data is transmitted via
the standard XLR-poles 1 and 2 – new DMX-cables are not necessary. RDM ready and conventional DMX
devices can be operated in one DMX line. The RDM protocol sends own packages in the DMX512 data feed
and does not influence conventional devices.
If DMX splitters are used and RDM control is to be used, these splitters must support RDM.
The number and type of RDM parameters depend on the (optional) RDM controller being used.
In general, the device supports the following commands and functions via RDM:
Device IP Addr
With this function the IP address of the device can be adjusted and changed as required.
Ctrl IP Addr
With this function the IP address of the controller can be adjusted.
Universe
With this function you can select the universe.
Protocol Set
With this function you can displays the protocol used.
Net Switch
With this function the device can be activated to receive the Art-Net signal.
Fan Set
Adjust ventilation fans mode
With the function "Fan Set", you can adjust the ventilation fans mode for the fans.
LCD. Set
Display shutt off time
With the function "Backlight", you can shut off the display after 2 to 60 minutes.
Display reverse
With the function "Flip Display", you can flip the display by 180° for a better view when the fixture is hung
from the truss or a ceiling.
Key lock
With this function you can lock the keys of the Control Board to e.g. prevent menu tampering. If this function
is activated, the keys will be automatically locked in 15 seconds from the last command. In order to
deactivate or temporarily deactivate the keylock function, press the Mode button for 3 seconds to regain
access to the menu commands.