Herunterladen Inhalt Inhalt Diese Seite drucken

Automatic Cleaning System; Installer Prescriptions Regarding Burner Servicing And Maintenance; Important Recommendation For Long-Lasting And Correct Operation Of The Burner; Controller Unit - Sunsystem Burnit Pell series Technischer Datenblatt Montage- Und Bedienungsanleitung

Pelletbrenner
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 15
determined by the intervals preset on the control
panel taking into account the heating value, size and
density of the pellets.
EN

8.3. Automatic cleaning system.

The "Pell" pellet burner is equipped with innovative
automatic cleaning system for the combustion
chamber. Thanks to a powerful cleaning motor built
in the burner body, air is being blown in at high
speed and rate thus removing all residues – ash,
noncombustible inclusions, etc. built up into the
combustion chamber of the boiler. These automatic
cleaning cycles last several seconds and can be
additionally adjusted as well as their repeat rate
depending on the load of the burner.
8.4.
Installer
prescriptions
servicing and maintenance
Before the heating season it is mandatory to check up
and clean the burner and its components.
It is mandatory to clean up the combustion
chamber of burner using the scraper brush from the
maintenance kit. In case of combustion chamber
orifices clogged by non-combustive material, those
should be released using a bodkin. Clean thoroughly
the inner combustion chamber using the scraper
brush to remove all deposits on the metal surface.
Use a vacuum cleaner to remove all sand and ashes
from inside the combustion chamber. Check integrity
of gasket between outer combustion chamber and
closing hatch, replace if compromised.
It is mandatory to clean dust off main fan and
controller board.
8.5. Important recommendations for long-lasting
and correct operation of the boiler
- For assembly and installation of the burner follow
the requirements in this manual.
- Use only recommended in this manual fuel.
- Disassemble the burner from the boiler body before
clean it. Depending on fuel and burner settings,
clean the pellet burner once a month.
- User`s training for operation and maintenance of
burner is performed by an authorized installer or
service shop.
Failure to observe the installation and
operating requirements described in the
manual and the service booklet voids the
warranty.
Type of
maintenance
Cleaning
chamber by poker and scraper
Weekly
brush.
TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL
regarding
burner
Procedure
Duty of:
of
combustion
User
Dismantling of combustion
chamber
Cleaning
Monthly
chamber by scraper brush and
vacuum cleaner. Replacement
of gasket if faulty.
Complete disassemble and
clean the burner. To replace
Yearly
all the trimmings (see schemе
10, point 11.2)
Diagram 8. Dismantling of the combustion
chamber housing.
9. CONTROL UNIT
9.1. Controller view. Explanation of buttons and
indicators. LCD screen:
The controller screen displays the
information for the operation of
the facility.
Explanation of buttons:
Button "F"
Apply for:
- exit of the current menu
- taking back to main screen
- burner transfer from one condition to another.
Button „Enter"
the different parameters in a screen and adjust the
corresponding parameter.
Buttons
„Navigation
„Navigation arrow Down"
the value of a parameter in the menu and to move to
the next menu page .
Display symbols explanation:
Auto Clean symbol appears in right upper
part of display. Active auto cleaning symbol
means boiler automatic cleaning mode.
Crossed-out flame symbol appears in upper
right part of display. Means that the boiler
enters into Extinguish mode.
CH priority /Radiator/ symbol appears in
upper part of display. Means than Central
Heating priority is set to heat up the central
heating.
Domestic Hot Water /shower/ priority symbol
appears in upper part of display. Means than
DHW priority is set to heat up the domestic
hot water. When set DHW temperature is reached,
DHW pump stops and CH pump is activated.
Parallel pumps /shower and radiator/ symbol
appears in upper part of display. Means that
is set equal priority to both pumps. They
10
housing
(A).
of
combustion
User /
Installer
Installer
function button.
– used to navigate between
arrow
Up"
– Used to change
and

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis