Attention! The fitting must be installed, flushed and
tested after the valid norms.

Operation

The mixer is actuated by lifting the lever head.
Swivel to the left = hot water, swivel to the right =
cold water.
Technical Data
Operating pressure:
Recommended operating pressure: 0,1 - 0,5 MPa
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Rate of flow 0,3 MPa:
(1 MPa = 10 bars = 147 PSI)
Hansgrohe single lever mixers can be used together
with hydraulically and thermically controlled
continuous flow heaters if the flow pressure is at
least 0,15 MPa.
To adjust the hot water limiter on single lever mixers,
please see page 14.
No adjustment is necessary when using a continuous
flow water heater.
Fault
Mixer stiff
Mixer dripping
Hot water temperature too low
No cold water
Instantaneous water heater starts
up when cold water is selected
English
max. 1 MPa
1,6 MPa
max. 80° C
65° C
approx. 32 l/min
Cause
- Cartridge defective, calcified
- Cartridge defective
Sedimentation
- Hot water limiter incorrectly set
- Crossflow
Spare parts (see page 3)
1
handle Talis E²
1.1 screw cover
2
handle Metropol S
3
handle Fcus S
4
handle Talis S / Talis S²
5
handle Metris S
6
escutcheon
7
flange
8
fixing screw
9
sub plate
10
nut
11
cartridge cpl.
12
locking screw
13
seal
14
screw M5 x 20 (4)
15
noise reduction
16
extension set 25 mm
17
extension set 22 mm
XXX = Colors
000 chrome plated
880 satin chrome
Remedy
- Exchange cartridge
- Exchange cartridge
- Set hot water limiter
- Exchange seal (13),
31692000
96338000
14895XXX
31793000
32092000
31093000
98792XXX
98790XXX
96454000
98793000
98796000
92730000
96059000
95008000
96525000
94073000
13595000
13597XXX
o-ring seal (16x2)
7

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis