Preventive Maintenance Schedule; Troubleshooting - Bauhaus DIESELHEIZER 10 Technische Daten

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 12
WARNING: BEFORE PERFORMING ANY MAINTENANCE OR REPAIRS, DISCONNECT
THE POWER SUPPLY CABL FROM THE MAINS AND MAKE SURE THAT THE

10. PREVENTIVE MAINTENANCE SCHEDULE

COMPONENT
Fuel tank
Empty and rinse the tank with clean
fuel every 150-200 working hours
Air outlet and anti-
Clean and replace according to
dist filters
necessity
Air inlet filter
Clean or replace every 500 working
hours or when necessary
Fuel filter
Clean or replace every 2 working
seasons or when necessary
Igniter
Clean or replace every 1.000
working hours or when necessary
Fan blades
Clean and replace according to
necessity

11. TROUBLESHOOTING

PROBLEM
The generator
1. Generator blocked
does not start
2. Starter switch in "OFF" position
3. No power supply
4. Power supply cable interrupted
5. Control card blocked
6. Incorrect setting of the room
The motor starts
1. No fuel
but the flame is not
2. Incorrect pump pressure
triggered
3. Igniter dirty
4. Fuel filter dirty
5. Nozzle dirty
6. Presence of foreign
7. Flame control device broken
The fan is blocked
1. Pump rotor blocked
or turns slowly
2. Motor broken
ATTENTION: ON RE-START, MAKE SURE THE GENRATOR HAS BEEN SET VIA THE
GENERATOR IS COLD.
MAINTENANCE FREQUENCY MAINTENANCE PROCEDURE
POSSIBLE CAUSE
(0)
thermostat (where present)
substances in the tank
RELATIVE BUTTON. (SEE PAR. 6.2)
Empty and rinse the tank with
clean fuel (SEE PAR. 9)
Contact after-sales centre
Contact after-sales centre
Contact after-sales centre
Contact after-sales centre
Contact after-sales centre
POSSIBLE SOLUTION
1. Reset the generator (SEE PAR.
6.2)
2. Take the "ON/OFF" switch to the
"ON" (|) position (SEE FIG. 3-4)
3. Insert the power supply cable into
the mains socket correctly
4. Contact after-sales centre
5A. Reset the generator (SEE PAR.
6.2)
5B. Contact after-sales centre
6. Act on the room thermostat, taking
it to a higher temperature than that
of the work environment (SEE FIG.
5)
1. Top-up fuel and reset the generator
2. Regulate the pressure of the
compressor (SEE PAR. 7)
3. Contact after-sales centre
4. Contact after-sales centre
5. Contact after-sales centre
6. Empty and fill the tank with clean
fuel (SEE PAR. 9)
7. Contact after-sales centre
1. Contact after-sales centre
2. Contact after-sales centre