RULES AND REGULATIONS

The programming and installation of electrical systems must be
carried out according to the rules, directives, requirements and
regulations in force in the respective country.
The technical activities necessary and related to the installation
KNX bus must only be carried out by highly specialized personnel.
The installation and connection of the bus line and the tools used
must be carried out in accordance with the regulations in force.
Any applicable safety regulations, such as accident prevention
regulations or laws on work equipment or tools, must also be
respected even concerning the means of production and related
installations.
DESCRIPTION
The V2KNX01 device is an innovative V2 product that allows
you to insert a V2 control unit of the gate line into a KNX home
automation network.
• Connection to the V2 control units via ADI connector
• KNX bus connection via KNX spring clamp
• Signalling LED used for "communication in progress"

TECHNICAL SPECIFICATIONS

Bus Voltage
Power consumption from the bus
Power absorption by bus
Protection
Isolation between bus and ADI terminal

INSTALLATION

m
Make sure the control unit is off
1. Insert the module's flat cable into the ADI connector of the
control unit
2. Secure the module inside the control unit container using the
piece of Velcro supplied
3. Connect the KNX network via the red/black connector and
perform the normal procedure for networking a KNX device.
The description of the parameters and the communication
objects, which may be used, can be found in the
"Commissioning" chapter.
NOTE: Through the KNX network, you can simulate a safety
device (photocell, safety edge or emergency stop button) with
a device connected to the network, or send an alarm state or
function in progress.
If you intend to use one of these functions (datapoint 8, 10 or
11), you must enable the ADI port from the central menu:
1. Enter programming
Adi
2. Select the
parameter and press MENU
Si
3. Choose the
option and press MENU to confirm:
EI3
appears on the display
4. Press MENU again
m
CAUTION: If you do not use this function you must not
Adi
enable the
parameter otherwise the control unit will test the
device, which does not respond, and goes into error by displaying
Er10
).
COMMISSIONING
To enable the V2KNX-01 interface, you must configure it using
the ETS Engineering Tool Software.
The product database is available in the reserved area of the V2
Website www.v2home.com (file V2KNX01-DB.knxprod).
The operating parameters and communication objects are divided
into two pages: the first contains parameters and objects of
general use, which can be connected to common KNX devices;
while the parameters and objects contained in the second page
are dedicated to exchanging information between V2 devices.
- 7 -
21-32Vdc
5mA
150mW
IP30
4kV