Installation radio code test
I
If you are adding to your system, you should first activate the system's test
mode to carry out this test. To do this, refer to the installation guide for the
alarm system provided with the unit.
Œ
Briefly press the detector's test button.

Check that the control panel emits:
an audible message and an indicator lamp lights up on the control panel,
G
or a voice message
G
If the control panel does not properly respond, first recode the detector. Then if the
problem persists, recode the control panel and try again.
llocating a motion detector to a group
I
The group 1 detectors are factory-set.
These settings can be modified in accordance with the table below.
Group
Part set/Fully set mode
Group 1
ctive when Part Set
or
and Fully Set
Group 1
larm triggered
immediate
immediately
Group 2
ctive when Part Set
or
and Fully Set
Group 1
larm triggered
delayed
immediately or with delay
Group 3
ctive when Fully Set
or
Inactive when Part Set
Group 2
larm triggered
immediate
immediately
Group 4
ctive when Fully Set
or
Inactive when Part Set
Group 2
larm triggered
delayed
immediately or with delay
Œ
ssign the detector the chosen group by programming the relevant code
1
0
Start
programming
by pressing
both keys
simultaneously
until the indicator
light goes out.
"Group X
Intrusion".
Base unit in
1
0
Press both keys
simultaneously
again until the
indicator light
goes out.
Base unit in
independent groups
mode
ctive when Group 1 Set
larm triggered
immediately
ctive when Group 1 Set
larm triggered
immediately or with delay
ctive when Group 2 Set
larm triggered
immediately
ctive when Group 2 Set
larm triggered
immediately or with delay
Enter the sequence
of 4 short key
presses
corresponding
to the number
of the detector you
are programming.
44
Code for
selected group
0 0 1 0
0 1 1 0
1 0 1 0
1 1 1 0
1
0
Confirm the
programming
by pressing both keys
simultaneously until
the indicator light goes
out. The indicator
light will come on for
5 seconds to indicate
the programming
has been successful.