•  Regulation of the Minister of Infrastructure of 12 April 2002 concerning the technical requirements of the buildings and their
location ( Journal of Laws no 75, item 690 of 2002 and Journal of Laws no 109, item 1156 of 2004)
•  Standard PN-EN 13229:2002 "Inset appliances including open fires fired by solid fuels. Requirements and test methods"
•  Standard PN-B-02413:1991 "Heating and heating systems – Protection of open vented heating system – Requirements"
•  Standard PN-EN 1443:2005 – Chimneys. General requirements.
•  Standard PN-EN 1457-2:2012 – Chimneys – Clay/Ceramic flue liners – Part 2: Flue liners operating under wet conditions.
Requirements and test methods.
In accordance with the Regulation of the Minister of Infrastructure (§ 132, para. 3), wood-burning fireplaces with closed
fireplace inserts, can only be installed in single-family buildings, residential building on a farm, leisure homes and in low-rise
multifamily buildings, in rooms that:
•  have volume resulting from the ratio 4 m3/kW of the nominal heat output of fireplace, but not less than 30 m
•  meets the venting system requirements, as referred to in § 150, para 9 of regulation,
•  have chimney ducts as described in § 140, par. 1 and 2 and § 145, par. 1 of the regulation,
•  allows flow of air into the fireplace in the amount of at least 10 m3/h per 1 kW of nominal heat output of fireplace – for
fireplaces in a sealed enclosure
In accordance with the Regulation of the Minister of Infrastructure (§ 150, para. 9 and 10), in room where are installed solid fuel
fireplaces with combustion air intake from the room and with gravity flue, the use of mechanical exhaust ventilation is prohibited.
This requirement does not apply to the rooms, where balanced ventilation system or over-pressure ventilation system, has been
installed.

2. intended Use

Cast iron inserts and cast iron inserts with water jacket are appliances for solid fuel. They can be installed either as
a standalone or as an additional heat source.
!
warninG! inSert w9, w9a and L12 can be inStaLLed onLy aS an additionaL SoUrce oF heat.

3. description of the device

Cast iron fireplace insert segments are composed in whole, sealed with sealant and bolted. The furnace door is sealed with
heat-resistant glass. In the bottom of the burning chamber is cast iron grate. Under the grate was built on tin, pop ash pan. The
front part of the ash is equipped with a primary air damper to the combustion process. The damper can be moved in two extreme
positions and is used to control the amount of primary air fed into the burning chamber grate. A fireplace insert is equipped in the
regulation in the flue through the use of damper lever adjustable in position to an existing chimney draft. Operation of the fireplace
is by mounting it with non-combustible construction, so that the visible part of the contribution of the anterior wall of the door with
heat-resistant glass. When the door-loads of fuel as well as the observation of the flame.
!
FirepLace, excLUdinG the contribUtion oF w9, w9a and L12, can FUnction in
Fireplace with water jacket
The rear, side and upper walls of the burning chamber of is water jacket with a wall thickness of 25-30 mm. In upper part
of water jacked are located special pipes. The purpose of the pipes is the ensure of adequate heat transfer surface area and to
improve the circulation of water in the water space of the water jacket. During normal operation, the flue gases are "washing" the
walls of the burning chamber and then a niche and external surfaces of pipes, and then into the flue and chimney. Back to the
"cold" water to the fireplace water system is realized by means of the lower ports (left or right) welded to the side walls of water
jacket. Discharge of heated water from the water jacket is made left or right (otherwise than return) top discharge port. The second
connector is used to connect pipes of safety.
4. assembly and installation of a fireplace insert
the flue gas outlet
Before connecting the fireplace insert read this manual and check the completeness of its equipment. To ensure safe and
economical operation of the fireplace is in good working order and properly adjusted in terms of the diameter as well as a good
seal duct, made according to the building rules. Before connecting the fireplace insert to the chimney, it is necessary to receive the
flue by a qualified chimney sweep. The chimney at the bottom, below the level of connection of the oven should be equipped with
non-combustible, double access door.
If necessary, clean the chimney. Check that the flue type is suitable for the purpose for which it is used. Check the seal or
bending is not too large and that the section allows you to make a connection via tube having the same diameter as the nozzle of
fireplace.
!
note: yoU can not connect More than one deVice to the FLUe GaSeS oUtLet.
42
a continUoUS coMbUStion SySteM.
,
3