Descrizione
Description
IT
EN
1
2
3
4
5
6
EN
The monitor is designed for use in colour systems, in the SB2
section downstream of art. 4888C, or in systems without mixer, such
as the system with 2-wire Kit or art. 1210.
1. S1 User code programming microswitches
2. S2 Button and function programming microswitches (marked with
a red corner)
DIP 1-2-3-4 for button function programming
DIP 5-6 access to programming
DIP 7 for power supply voltage management Default=OFF
(Diagrams and variants on page 6)
For systems with 2-wire Kit or art. 1210, set DIP 7 to ON.
DIP 8: ON Secondary monitor
OFF Main monitor (default)
A maximum of 1 main monitor can be set in systems with
2-WIRE Kit or art. 1210, and 2 main monitors in systems
with art. 4888C.
3. Loudspeaker volume adjustment (for setting intercom audio only)
4. CV5 Video closing jumper
5. Pin for securing terminal block
6. Space for housing the operation accessory for keys
Art. 6733W available to purchase separately.
Terminal block for system connection:
L L bus line connection terminals
CFP1 CFP2 Floor door call input
NL
De monitor wordt gebruikt in SB2 kleurensystemen, achter de
mixer art. 4888C, of in systemen zonder mixer type Kit 2-draads
systeem of met art. 1210.
1. S1
Microschakelaars
gebruikerscode
2. S2 Microschakelaars voor het programmeren van toetsen en
functies (gemarkeerd met een rode hoek)
DIP 1-2-3-4 voor het programmeren van de functies van de toetsen
DIP 5-6 toegang tot de programmeringen
DIP 7 voor het beheer van de voedingsspanning. Standaard=OFF
(Zie schema's en varianten vanaf pag. 6)
Bij Kit-2-draads systemen of met art.1210 moet DIP 7
worden ingesteld op ON.
2
Description
FR
voor
het
programmeren
Beschrijving
Beschreibung
NL
DE
IT
Il monitor è da utilizzare in impianti a colori nella tratta SB2 dopo
il miscelatore art. 4888C; oppure in impianti senza miscelatore tipo
sistema Kit 2 fili o con art. 1210.
1. S1 Micro-interruttori per programmazione codice utente
2. S2 Micro-interruttori per programmazione pulsanti e funzioni
(identificato da un angolo rosso)
DIP 1-2-3-4 per programmazione funzioni pulsanti
DIP 5-6 accesso programmazioni
DIP 7 per gestione tensione di alimentazione Default=OFF
(Schemi e varianti da pag. 6)
In impianti Kit-2 fili o con art. 1210 impostare DIP 7 su ON.
DIP 8: ON Monitor secondario
OFF Monitor principale (Default)
È possibile impostare max 1 monitor principale negli
impianti Kit 2 FILI o con art. 1210 e max 2 monitor
principali negli impianti con art. 4888C.
3. Regolazione volume altoparlante (Solo per settaggio fonica
intercomunicante)
4. CV5 Jumper chiusura video
5. Pin per ancoraggio morsettiera
6. Spazio per alloggiamento accessorio per funzionamento pulsanti
aggiuntivi
Morsettiera per connessione impianto:
LL Morsetti di connessione linea bus
CFP1 CFP2 Ingresso chiamata da piano
FR
Utiliser le moniteur sur des installations couleurs, sur le tronçon
SB2, après le mélangeur 4888C ; ou sur des installations sans
centrale vidéo, type système Kit 2 fils ou avec 1210.
1. S1 Microswitches pour la programmation du code résident
2. S2 Microswitches pour la programmation de touches et fonctions
(marked with a red corner)
DIP 1-2-3-4 de programmation des fonctions des boutons
DIP 5-6 accès à la programmation
DIP 7 de gestion de la tension d'alimentation. Par défaut=OFF
(Schémas et variantes à partir de la page 6)
Pour les systèmes Kit-2 fils ou avec 1210, régler DIP 7
sur ON.
DIP 8 : ON Moniteur secondaire
OFF Moniteur principal (Par défaut)
Possibilité de configurer 1 seul moniteur principal sur les
systèmes Kit 2 FILS ou avec 1210, et 2 moniteurs principaux
au maximum sur les systèmes équipés de 4888C.
3. Réglage du volume du haut-parleur (Uniquement pour le réglage
de la phonie d'intercommunication)
4. CV5 Cavalier de débranchement vidéo
5. Pin d'ancrage bornier
.
6. Espace pour loger l'accessoire faisant fonctionner les touches
. (Art. 6733W disponible à part)
Bornier pour la connexion de l'installation :
L L Bornes de connexion ligne bus
CFP1 CFP2 Entrée de l'appel palier
DIP 8: ON Secundaire monitor
OFF Hoofdmonitor (Standaard)
Er kan max. 1 hoofdmonitor worden ingesteld in de
Kit 2-DRAADS systemen of met art. 1210 en max. 2
van
de
hoofdmonitors in systemen met art. 4888C.
3. Volume van de luidspreker regelen (alleen voor geluidsinstelling
intercom)
4. CV5 Jumper voor het afsluiten van het videosignaal
5. Pen voor bevestiging van het aansluitklemmenbord
6. Ruimte voor het plaatsen van een accessoire voor de werking van
toetsen
Klemmenblok voor aansluiting van de installatie:
L L Klemmen voor aansluiting buslijn
CFP1 CFP2 Ingang voor etagebel
Descripción
ES
(Art. 6733W acquistabile separatamente).
Apart verkrijgbaar (Art. 6733W)
Descrição
PT

Werbung