1.

TECHNICAL DATA

Power supply
Absorption
Thrust
Condenser
Max run
Door speed
Max door weight
Service class
Min number of
consecutive cycles
Intermittence
Temperature
Degree of protection
Control panel
2.
REFERENCE TO ILLUSTRATIONS
The given operating and performance features can only be gua-
ranteed with the use of DITEC accessories and safety devices.
2.1 Standard installation references (fig. 1)
[1]
Radio
[2]
Flashing light
[3]
Key selector
[4]
Connect power supply to an type-approved omnipole
switch with a contact opening gap of no less that 3 mm
(not supplied)
Connection to the grid is made with independent channels
and separated from the connections to the control and
safety devices.
[5]
Rubber edge - sensitive edge
[6]
Geared motor + control panel [only CROSS18E-18VE]
[7]
Photocells
2.2 Geared motor references
[8]
Motor
[9]
Casing
[10] Control panel
[11] Manual release
[12] Rotary stop group
[13] Lever stop group
[14] Magnetic limit switch group
[15] Pinion
[16] Pinion casing
[17] Rack stop
[18] Magnetic limit switch bracket
[19] Limit switch bracket
2.3 Accessories
CROSSCRI
Galvanised steel rack
CROSSTC
Chain drive kit
CAT1
1/2" chain (5 m)
CATG
1/2" chain joint
3.

INSTALLATION

Unless otherwise specified, all measurements are expressed
in millimetres (mm).
CROSS18
CROSS18E
230 V~ / 50 Hz
230 V~ / 50 Hz
3 A
1200 N
25 µF
11 m
0,2 m/s
1800 kg
4 - INTENSIVE
4 - INTENSIVE
50
S2 = 30 min
S2 = 30 min
S3 = 50%
S3 = 50%
-20 °C / +55 °C
-20 °C / +55 °C
IP24D
E1A-LOGICM
E1A (incorporated)
11
CROSS18VE
230 V~ / 50 Hz
3 A
3 A
1200 N
1200 N
25 µF
25 µF
20 m
20 m
0,2 m/s
0,2 m/s
1800 kg
1800 kg
4 - INTENSIVE
50
50
S2 = 30 min
S3 = 50%
-20 °C / +55 °C
IP24D
IP24D
LOGICM (incorporated)
3.1 Preliminary checks
Check the stability of the wing (derailing and lateral falls) and
the sliding wheels and that the upper guides do not cause any
friction.
The sliding guide must be securely fixed to the ground for the
full length within the doorway and must have no irregularities
that could hinder the movement of the gate.
The opening and closing stops must be fitted.
Note: make sure that the gate can not exit the sliding guides
and fall.
If the gate has slits, make sure they are covered to prevent
shearing points.
Safety device should be installed at the end of the wing to reduce
the collision force.
3.2 Base plate position
-
Insert the anchor ties onto the base plate and fix them with
the supplied nuts.
(*) CROSSCRI X = 40 mm
(**) CROSSTC 70 mm
Ø50x2
min
60
X+20 (*)
70 (**)
Ø12.5x2
CROSS19V
400 V~ / 50 Hz
1,2 A
1500 N
-
20 m
0,2 m/s
1800 kg
4 - INTENSIVE
50
S2 = 30 min
S3 = 50%
-20 °C / +55 °C
IP24D
E1T
OPENING
X+20 (*)
70 (**)
240
270
Ø12.5x2
OPENING
Ø50x2
240
min
150
270
CROSS18-19 - IP1984