Choose the filter class according to table 1 and 2 and make sure that the toxic concentration does not exceed the percentage
shown in this table. When particles or aerosols are present, choose a particle filter according to the table 2, or a combination
filter according to table 1 and 2.
-
It is important that the "Multiple" of the limit value in Table 3 is not exceeded. On the use of AX filters against low-boiling gases,
the currently applicable limitation of use of gas filters against organic compounds with a boiling point < 65°C must be observed.
The limitation of use on AX filters is enclosed with the AX filters.
-
Unsatisfactory warnings regarding dangerous stuff (material) require special rules.
-
Check if the expiration date shown on the filter has not been exceeded.
-
Unpack the filters and remove the sealing covers.
-
Screw the filter into the screw thread.
-
Check if the impermeability corresponds to the information in the operating instructions for the mask and/or for the powered air
purifying respirator system.
-
Check the suitability of components used and here from the resulting device class (see Table 5) for the application purpose.
-
Check the filter for visible damage.
-
Check the storage time expiration date for gas- and combination filters (see filter label).
-
Exchange damaged parts immediately.
-
Do never use unsealed or damaged filters.
-
Replace non factory sealed filters after 6 months, at the latest.
-
Only gas and combination filters stored sealed may be reused on certain conditions (at the utmost 6 month).
-
Check if the 6-monthly time limit of usage for used gas and combination filters is observed.
-
If the breathing resistance becomes excessive, exchange the particle filter.
-
Upon perception of smell or taste, exchange gas and combination filters immediately. Consult the supervisor upon smell or
tasteless gases.

AREAS OF USE

The following areas of use are applicable for non powered equipment:
Table 1: Gas filters
Type
Colour code
A
Brown
B
Grey
E
Yellow
K
Green
AX
Brown
Hg
Red
IPR
Orange & White
Table 2: Particle filters
Type
Colour code
P R
White
Different types can be combined in one filter, e.g. A2B2E2K2P3
R = Filters may be used on multiple shifts.
The additional identification mark "R" means that, based on supplementary tests according to EN 143:2000/A1:2006 is
proven, particle filters and respectively the particle filter part of a combination filter are reusable after aerosol exposition
(use on multiple shifts). Exchange the filter when the breathing resistance is unpleasant high.
AREAS OF USE FOR POWERED EQUIPMENT
Main use
Organic gases and vapours with a boiling point >
65°C
Inorganic gas and vapours (no CO)
Sulphur dioxide and other acidic gases and vapours
Ammonia and organic ammonia derivative
Organic gases and vapours with a boiling point
< 65°C
Mercury vapour
Iodine and radioactive dust
Main use
Particle
Class
> 99.95% 95 l/min NaCL (mmd.=0.6 µm)
3
> 99.99% 95 l/min paraffin oil (mmd.=0.4 µm)
NOTE
2
Max. permissible gas
Class
concentration
1
0.1% in vol
2
0.5% in vol
1
0.1% in vol
2
0.5% in vol
1
0.1% in vol
2
0.5% in vol
1
0.1% in vol
2
0.5% in vol
Filter efficiency