Guide to buttons
Press Length (s)
2-5
5-10
10-20
20-30
30+
Press Length (s)
0-1
5-10
10-15
15-30
30+
OEM lock - press Setup button for 30+ seconds -
4 x red LEDs should light to confirm.
repeat procedure to remove the lock.
Press Length (s)
2-5
5-10
10-15
15+
Action
Forces unit into float mode. Press again to take out of float mode.
Turns unit on / off toggle.
Battery type select - use SETUP / SELECT to toggle between types. Both to confirm.
Change operational on/off voltages - use both buttons to scroll between voltages.
Reset unit to default - press and hold both buttons for 2 seconds to confirm.
Action
Change to status fault display / back to Voltage display mode.
Toggles between 1/2 and 1/1 (full) power.
Set Auto Regen. time - use either buttons to toggle between the preferred time.
Live output voltage (power supply mode) - press SELECT to change to LED 24.
OEM lock - disables further adjustment of unit's functions.
Action
Night mode = 1/2 power for 8 hours, then back to full power.
Enter standby mode. To take out of standby, repeat.
Display software version (displayed in binary on display).
SVEM - Stationary Vehicle Engage Mode
Stationary Vehicle Engage Mode
Pro Batt Ultra starts charging when input is >13.1V.
Turns off when input is <13.0V.
7
this mode prevents operators tampering with the unit's
settings when in the field. The OEM / fitter can set the
unit up as they desire first, the settings shall be stored,
then they can apply this lock.
SVEM*