Check the plate, read the pressure and verify that the description of the nozzle installed corresponds to the one supplied
by the manufacturer.

Connection with natural gas H G20

The connection pressure for natural gas is 20 mbar.
Check the plate, read the pressure and verify that the description of the nozzle installed corresponds to the one supplied
by the manufacturer.

CHECKING PRIMARY AIR TO THE MAIN BURNERS AND PILOT NOZZLES

All the burners are fitted with an air regulator by means of which the primary air can be varied thanks to an adjustable
bush that can be locked with a screw. In the "Burner Technical Data" table you will find the approximate values for the
"h" parameter (primary air). The flow of primary air must be regulated so there is no detachment of the flame when the
burner is cold or a return of the flame when the burner is hot.
The pilot air is regulated when the appliance is tested and inspected for the gas it is set for.
If you are going to change to a different type of gas, regulate the air by means of the adjusting bush until the flame stops
sputtering and becomes an intense blue colour.
TP Burner max 7 kW - min. 4 kW
Burner Injector 1/100 mm
Min. output adjustment 1/100 mm
Pilot Injector 1/100 mm
Consumption
Burner max 4 kW -min 1,5 kW
Burner injector 1/100 mm
Min. output adjustment 1/100 mm
Pilot Injector 1/100 mm
Consumption
Primary air h=mm
Burner max 7 kW -min 1,8 kW
Burner injector 1/100 mm
Min. output adjustment 1/100 mm
Pilot Injector 1/100 mm
Consumption
Primary air h=mm
Burner max 10 KW-min 2,3 kW
Burner injector 1/100 mm
Min. output adjustment 1/100 mm
Pilot Injector 1/100 mm
Consumption
Primary air h=mm
Oven Burner max 8,5 kW- min 2.2 kW
Burner injector 1/100 mm
Min. output adjustment 1/100 mm
Pilot Injector 1/100 mm
Consumption
Primary air h=mm
Oven Burner max 13 kW -min 3,5 kW
Burner injector 1/100 mm
Min. output adjustment 1/100 mm
Pilot Injector 1/100 mm
Consumption
Primary air h=mm

RULES FOR CONVERTING AND INSTALLING FOR OTHER TYPES OF GAS

Our appliances are tested and regulated with liquid gas (see data plate).
GB

"BURNERS" TECHNICAL DATA TABLE

12.8 kWh/KG
G30
BUTANE
30 mbar
kg/h 0,552
kg/h 0,313
kg/h 0,547
kg/h 0,781
kg/h 0,664
kg/h 1,016
IE
12.8 kWh/KG
G31
PROPANE
37 mbar
130A
130A
100
100
20
20
kg/h 0,544
95
95
60
60
20
20
kg/h 0,313
3
3
130
130
65
65
20
20
kg/h 0,547
open
open
155
155
75
75
20
20
kg/h 0,781
open
open
145
145
75
75
19
19
kg/h 0,664
20
20
180
180
100
100
19
19
kg/h 1,016
25
25
45
3
9.45 kWh/m
st.
G20
NATURAL GAS H
20 mbar
195
adjustable
30
3
m
st./h 0,740
145
adjustable
35
3
m
st./h 0,423
0
195
adjustable
35
3
m
st./h 0,740
1
230
adjustable
35
3
m
st./h 1,058
1
220
adjustable
27
3
m
st./h 0,899
20
290
adjustable
27
3
m
st./h 1,376
25