Herunterladen Inhalt Inhalt Diese Seite drucken

Descaling Procedure; Descaling Cycle - Philips HD7854 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für HD7854:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 53
EnglisH
24
Each descaling mixture can be used only once. After use, the descaling
mixture is no longer active.
Philips SENSEO
has developed a special descaler (HD7012, HD7011,
®
HD7006) for SENSEO
descaler, visit our website www.philips.com.
Never use a descaling agent based on mineral acids such as sulphuric
acid, hydrochloric acid, sulphamic acid and acetic acid (e.g. vinegar). These
descaling agents will certainly damage your SENSEO

Descaling procedure

The descaling procedure consists of three cycles:
-
Descaling cycle (approx. 35 minutes)
-
Rinsing cycle with used pod (approx. 3 minutes)
-
Rinsing cycle without used pod (approx 3 minutes)

Descaling cycle

1
Mix 50 grams of citric acid with 1 litre of water in a measuring jug.
Stir until the powder has completely dissolved.
2
Remove the water reservoir.
3
Fill the water reservoir with the descaling mixture.
Then put the water reservoir back onto the coffee machine.
4
Remove the milk container unit from the machine.