Herunterladen Inhalt Inhalt Diese Seite drucken

Fagor SR-11 Bedienungsanleitung Seite 103

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 175
The EDIT menu is shown below. All programmes can be edited from this menu,
allowing the user to modify all the parameters shown in the following table as required and
for each programme.
PROGRAM: With the cursor in PROGRAM, use keys INC () and DEC () to move from one
programme to another (there are 9 programmes) and use SELECT key to confirm the programme
to be selected and the cursor moves to TEMP.
TEMP: With the cursor on TEMP, use keys INC () and DEC () to modify the temperature of the
previously selected programme. Use the SELECT key to confirm the change in the temperature
and the cursor moves to the next option, TIME.
TIME: With the cursor on TIME, use keys INC () and DEC () to modify the time of the
previously selected programme. Use the SELECT key to confirm the change in the time and
the cursor moves to the next option, AG. TIME.
AG. TIME: With the cursor on AG TIME, use keys INC () and DEC () to modify the time the
dryer takes to reverse the direction of the drum rotation. Use the SELECT key to confirm the
change in the time and the cursor moves to the next option, HUMIDITY. Values below 50" should
not be entered.
HUMIDITY: With the cursor on HUMIDITY, use keys INC () and DEC () to modify the relative
humidity of the previously selected programme. Use the SELECT key to confirm the change in
the relative humidity and the cursor moves to the next option, COOL TIME.
NOTE1: Although the humidity parameter is available, the appliance will only operate correctly
when it is fitted with the humidity control option, which is never the case in standard dryers.
NOTE 2: If the value entered is equal to 0, then the programme in question will operate with time
so that the dryer will end the cycle at the end of the time selected in the programme and will not
use the humidity sensor.
COOL TIME: With the cursor on COOL TIME, use keys INC () and DEC () to modify the
cooling time required on completion of the drying cycle of the previously selected programme.
Press SELECT to confirm the modification to the cooling time.
To exit the count menu, press the PROG key in the user menu, and with the cursor over
EXIT, and press SELECT to exit the technician's menu and go to the main Programme menu.
102
PROGRAM
TEMP
TIME
AG. TIME
HUMIDITY
COOL TIME
001
060
010
060
050
005

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis