MKD Product Safety Guide | 1   English

1.3 Product life cycle handling

1.3.1 Transport

Transport the MKD modules in accordance with IEC 61800-2 as follows:
The devices contain electrostatically sensitive components that can be damaged by incor-
rect handling. Electrostatically discharge yourself before touching the device. Avoid contact
with highly insulating materials, such as artificial fabrics and plastic films. Place the device
on a conductive surface.
If the packaging is damaged, check the unit for visible damage. Inform the shipper and the
manufacturer of any damage to the package or product.

1.3.2 Packaging

The MKD packaging consists of recyclable cardboard with inserts and a label on the outside
of the box.
Model
MKD-C003007-NA
MKD-C001007-CA
MKD-N060007, MKD-N060607,
MKD-N120007, MKD-N120607,
MKD-N121207
MKD-N240007
MKD-N480007

1.3.3 Storage

Store the MKD modules in accordance with IEC 61800-2 as follows:
10
Kollmorgen | kdn.kollmorgen.com | July 2019
Transport only by qualified personnel in the manufacturer's original recyclable packaging.
Avoid shocks while transporting.
Vibration/Shock: the modules are tested for environmental class 3M1 of IEC 60721-3-2.
Store at or below maximum stacking height of 8 cartons
Transport only within specified temperature ranges:
-25 to +70 °C, max. rate of change 20 K/hour, class 2K3.
Transport only within specified humidity:
maximum 95% relative humidity, no condensation, class 2K3.
Store only in the manufacturer's original recyclable packaging.
Store at or below maximum stacking height of 8 cartons
Store only within specified temperature ranges:
-25 to +55 °C, max.rate of change 20 K/hour, class 1K4.
Storage only within specified humidity:
5 to 95% relative humidity, no condensation, class 1K3.
Store the MKD in accordance with the following duration requirements:
Less than 1 year: without restriction.
More than 1 year: capacitors in the MKD-C must be re-formed before setting up and
operating the system. Re-forming procedures are described in the Kollmorgen
Developer Network (Forming).
Package Dimensions
(mm) HxWxL
580 x 350 x 170
580 x 350 x 170
580 x 350 x 110
580 x 350 x 110
580 x 350 x 140
Total Weight
(kg)
22.5
22.5
8.5
9.5
11.5

Quicklinks ausblenden: