Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting; Error Codes And Messages; Pcs Fault - LG D005KD1N111 Installationsanleitung

Vorschau ausblenden Andere Handbücher für D005KD1N111:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Error Codes and Messages

y Do not leave the ESS in the Fault standby state for a long time because of the battery discharge
may occur during the long standby state.
y If the battery fault occurs immediately after starting PCS it means Battery failure. Check the
battery SOC also voltage and fault information, and turn off the power of the ESS until service
action is taken.
y If the battery SOC is low the battery may charge from the grid for self-protection. (Emergency
Charging) This function is to prevent shutdown of the ESS, deep discharge and failure of the
Battery Extension Kit. An Emergency Charge is not an ESS fault.

PCS Fault

Code
Message
P400
AC MisWiring Fault
P401
Meter Comm Fault
P402
BMS Fault
P403
BMS Comm Fault
P404
PMS Comm Fault
P405
SDSP Comm Fault
P406
SDSP Fault
P407
Fan Fault
P408
Grid Relay Fault
P409
PV Over Voltage Fault
Description
Incorrect wiring grid connection
has detected
Communication error with the
energy meter
The BMS fault message from
battery.
Communication error with the
connected battery for over 10
seconds.
Communication error on PCS
system
Communication error with the
processing unit for over 15
seconds
P540(SDSP Detection) occurs 3
times
P541(Fan Detection) occurs 3
times
Fault occurs 3 times in the same
relay
Voltage level of the PV is lower
than the limitation and the state
is maintained for more than 10
minutes

Troubleshooting

Solution
Contact service center
Contact service center
Contact service center
Contact service center
Contact service center
Contact service center
Contact service center
Contact service center
Contact service center
Contact service center
63
4

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis