Herunterladen Inhalt Inhalt Diese Seite drucken

Installation; Installing/Replacing The Lamp; Danger To Life; Overhead Rigging - EuroLite PAR-56 Bedienungsanleitung

Cdm profi spot
Vorschau ausblenden Andere Handbücher für PAR-56:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

INSTALLATION

Installing/Replacing the lamp

Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 5 minutes).
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's
notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
For the installation, you need one CDM-T 150W G-12 lamp.
Procedure:
Step 1: Remove the colour filter frames by loosening the clip-to-hold clamps.
Step 2: Remove the screws of the protective shield on the housing and remove the protective shield.
Step 3: If replacing the lamp, remove the old lamp from the spot.
Step 4: Insert the new lamp in the lampholder.
Step 5: Replace the protective shild and tighten the screws.
Step 6: Replace the colour filter frames.

Overhead rigging

Please consider the EN 60598-2-17 and the respective national norms during the
installation! The installation must only be carried out by an authorized dealer!
The installation of the projector has to be built and constructed in a way that it can hold 10 times the weight
for 1 hour without any harming deformation.
The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net.
This secondary safety attachment must be constructed in a way that no part of the installation can fall down
if the main attachment fails.
When rigging, derigging or servicing the fixture staying in the area below the installation place, on bridges,
under high working places and other endangered areas is forbidden.

DANGER TO LIFE!

Only install the lamp with the device switched off!
Unplug from mains before!
CAUTION!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
Do not operate this device with opened housing!
DANGER TO LIFE!
14/31
42000920_V_1_0_2643.DOC

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis