Herunterladen Inhalt Inhalt Diese Seite drucken

Biss C/Ssi (Bml Sl1-Alz1-B/S0Zz-Ba; Ssi Interface; Biss Interface; Preset Input Signal - Balluff BML SL1-ALZ1 ZZ-ABA S284/KA-Serie Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
BML SL1-ALZ1- _ _ ZZ -ABA _ - S284/KA _ _
Absolute magnetic encoder system
6
BiSS C/SSI (BML SL1-ALZ1-B/S0ZZ-BA_ _-...)
For additional information about the interfaces
please refer to the document Interfaces for
BML Magnetic Encoder.
6.1

SSI interface

Data formats
Designation
Data length [bits]
Total data length [bits]
Tab. 6-1:
Data format with error bit
For information about status indication and error
monitoring see Section 5.2 on page 16.
The maximum SSI clock frequency is 4 MHz.
6.2

BiSS interface

Data formats
Designation
Data length [bits]
Total data length [bits]
Tab. 6-2:
Data format with error bit
In addition to the error and warning bit, transmission over
the BiSS interface is protected by a CRC. The status bits
are set according to the status (see Section 5.2 on
page 16).
Other BiSS interface properties
Maximum clock rate
Transmission type
Device BiSS ID
Manufacturer BiSS ID
EDS bank
Profile bank
BiSS profile
Area for user data
CRC polynomial
Tab. 6-3:
BiSS properties
18
english
Posi-
Error
Warning
CRC
tion
(active
(active
low)
low)
24
1
1
32
Posi-
Error
Warning
CRC
tion
(active
(active
low)
low)
24
1
1
32
10 MHz
BiSS bidirectional
"ML1000"
"BF"
5
6
BiSS BP3:
Standard Encoder Profile
Ab Bank 14 (0xE)
0x43 (hex), 67 (dec),
1000011 (bin)
6.3

Preset input signal

The beginning of the magnetic tape does not represent the
measured position 0, but rather the zero point can be at
any desired position within or outside of the magnetic tape.
Crossing the zero point causes a position jump (overrun)
and the error bit is set. Therefore the appropriate
measuring range should be set before operating.
To set the measuring range the sensor head must be
moved to the start of the measuring range. The Preset
connection is connected to the power source for at least
20 ms. The current position is set to 10 mm ±1 mm.
6
8.19 m
Offset not set
8.19 m
Offset set
6
Fig. 6-1:
Example for measuring range adjustment
The Preset connection is useful only for roughly setting the
start position. To set the position with greater accuracy the
Configuration Tool (see Section 9.5 on page 23) must be
used.
Path
Path

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Bml sl1-alz1 zz-aba s284/ka serie

Inhaltsverzeichnis