Commissioning
1. Make sure that the control unit and all components are correctly connected
(also see "„Assembly"").
2. Turn on the control unit using the main switch
3. Hold the vacuum tweezers with an easy, comfortable grip, e. g. like a pencil.
-
3
4. Use the push button
1 to activate the vacuum.
-2
3
An illuminated LED
means that the vacuum is active.
5. Press the button again to deactivate the vacuum.
-
3
The LED light
2 will not be illuminated (vacuum is off).
6

Service and Repairs

Cleaning and servicing
W
Seal all openings with suitable protective caps to prevent detergents from
penetrating the system.
W
Never use solvents or strong detergents. Only clean the product using a slightly
damp cloth. Only use water to do this and, if necessary, a mild detergent.
Maintenance
O Make sure that the system is not under voltage or pressure.
Cleaning or replacing the silencer
-
1
1. Unscrew the silencer
1.
-
1
2. Clean the silencer
1.
-
1
3. Screw the silencer
1 back onto the exhaust connection
If the vacuum capacity is not restored, exchange the silencer as described below:
-
1
1. Unscrew the silencer
1.
2. Screw the new silencer (1827000023)
If the vacuum capacity is not restored, please contact your authorized AVENTICS
dealer.
1
Exchanging the dirt filter (spare part)
1. Remove both coupling pieces from the dirt filter
-
1
2. Replace the dirt filter
8.
3. Place the coupling pieces back onto the dirt filter
7

Disassembly and Exchange

O Make sure that the system is not under voltage or pressure.
Danger of injury if disassembled or exchanged under pressure or voltage!
Disassembly or exchange when under pressure or electrical voltage can lead to
injuries and damage to the device.
O Make sure that the device is not under pressure or voltage before
disassembling the product or exchanging parts.
O Protect the device against being switched on.
Exchanging components
1. Remove the components from the control unit.
2. Install new components, see "„Assembly"", "„Maintenance"" and "Accessories".
8
Disposal
Scrap the device and fluid in accordance with local regulations.
9
Troubleshooting
Malfunction
Possible cause
Insufficient vacuum
Saturated dirt filter
capacity
Damaged silencer
O After checking the above points, please contact your authorized AVENTICS dealer
if the vacuum capacity is not restored.
-
1
15 and slide the
-
2
1.
-
1
15.
-
1
1 onto the exhaust connection.
-
1
8.
-
1
8.
CAUTION
Remedy
Replace dirt filter
Clean or replace silencer

10 Technical Data

General data
Control unit:
Electr. mains connection
115/230 V, 50 Hz
Power consumption
Approx. 30 W
Fuse 230 V
T 0.1 A, 250 V
Fuse 115 V
T 0.1 A, 250 V
Air supply
Approx. 4-6 bar, max. 7 bar
Vacuum
90% at 5 bar
Air consumption
60 l/min.
Medium
Filtered, oil-free air
Compressed air (connection) 4-6 bar (max. 7 bar)
Vacuum generation
Ejector principle
Ambient temperature
-10°C to +50°C
Air supply connection
G1/4" or Ø6 mm
Vacuum connection
G1/4" or Ø6 mm
Exhaust connection
G1/4" or Ø8 mm
Connection VP101
Miniature plug socket, 3-pin
Dimensions approx.
255 x 190 x 70 mm
Weight approx.
3.3 kg
Vacuum tweezers:
Dimensions approx.
Ø18 x 130 mm
Tubing or cable length
2 m
approx.
Weight approx.
40 g