F36 Adjusting partial opening
Adjusting as a percentage of total travel, during gate opening.
F37
Do not modify. Function unavailable.
F38
Do not modify. Function unavailable.
F39
Do not modify. Function unavailable.
F40
Do not modify. Function unavailable.
F41 Opening slow-down point
Percentage adjustment of the total travel, of the gate's opening slow-down point.
 This function only appears if the Encoder function is activated.
F42 Closing slow-down point
Percentage adjustment of the total travel, of the gate's closing slow-down point.
 This function only appears if the Encoder function is activated.
F43 Opening end-stroke point
Percentage adjustment of the total travel, of the gate's opening end-stroke phase starting point.
 This function only appears if the Encoder function is activated.
F44 Closing end-stroke
Percentage adjustment of the total travel, of the gate's closing end-stroke phase starting point.
 This function only appears if the Encoder function is activated.
F45
Do not modify. Function unavailable.
F46 Number of motors
For setting the number of motors connected to the control panel.
10= 10% of gate travel (default) /... / 80= 80% of gate travel
10= 10% of gate travel /... / 25= 25% of gate travel (default) /... / 60= 60% of gate
travel
10= 1% of gate travel /... / 25= 25% of gate travel (default) /... / 60= 60% of gate
travel
1= 1% of gate travel /... / 5= 5% of gate travel (default) /... / 10= 10% of gate travel
1= 1% of gate travel /... / 5= 5% of gate travel (default) /... / 10= 10% of gate travel
0 = Two gearmotors (default) / 1= One gearmotor