Diagnostic Tests

This section provides the information needed to access, select, and perform
Rimage Professional diagnostic tests. To perform any of the diagnostic tests, you
must be sure that the Professional is not in an error state.
Access and Select Diagnostic Tests
Access Diagnostic Test Mode
1.
Power on the Professional.
2.
Allow the system to fully initialize.

Note: It takes up to 5 minutes for the Professional to fully initialize.
3.
Open the front door.
4.
Press and hold the operator button until the operator panel displays
[BUTTON DIAGNOSTIC].

Note: Other status messages display on the operator panel while the
operator button is being held in Do not release the button until the
operator panel displays [BUTTON DIAGNOSTIC].
Release the operator button. The autoloader is in diagnostic test mode.
5.
Select a Diagnostic Test
1.
Press the operator button the same number of times as the test number
(indicated in the test title).
2.
Hold the operator button in on the last press to start the selected test.
For example, to start Diagnostic Test 3 (Calibrate Lift Home), press the
operator button three times and hold it on the third press.
 T ip: To display each diagnostic test number and name, press the
operator button at a rate that is slow enough to read the test on the
operator panel. If you hold the button too long, the test starts. If you
pass the desired diagnostic test, release the operator button and wait
for the autoloader to return to diagnostic mode
3.
Continue with the desired diagnostic test.