3.3. WIRING AND SAFETY OF BUILT_IN OVEN
The instructions given below must be followed without fail during wiring :
The earthing cable must be connected via the screw with the earthing mark. Supply
cable connection must be as shown in Figure 1. If there is no earthed outlet conforming
to regulations in the installation environment, call the Authorized Service
immediately.There is to install an all pole disconnector inside they supply circuit with a
contact openning of at least 3mm ( rated 16A).
The earthed outlet must be in close vicinity of the appliance. Never use an extension cord.
The supply cable should not contact the product's hot surface.
In case of any damage to the supply cable, make sure to call the Authorized Service. The
cable must be replaced by the Authorized Service.
Wiring of the appliance must be performed by the Authorized Service. H05VV-F type
supply cable must be used.
Faulty wiring may damage the appliance. Such a damage will not be covered under the
warranty.
The appliance is designed to connect to 220-240V~ electricty is different than the value
given above, call the Authorized Service immediately.
L
N
Figure1
8