Maintain the Rimage 2000i Series II
Select a Diagnostic Test
1. Press the operator button the same number of times as the test
number, holding the button in on the last press to start the selected test.
For example, to start Diagnostic Test 3 (Calibrate Diagnostic), press the
operator button three times and hold it in on the third press.
Tip: To display each diagnostic test number and name, press the
operator button at a rate that is slow enough to read the test on the
operator panel. If you hold the button too long, the test begins.
2. Continue with the desired diagnostic test.
Diagnostic Test 3 – Calibrate Diagnostic Test
This test uses one disc to calibrate the distance from the lift arm home
position to the supply bin.
1. Access and select diagnostic test 3. Refer to
Mode
on page 17.
2. Press the operator button three times and hold it in on the last press.
[STARTING TEST RELEASE BUTTON] displays on the operator panel.
3. Release the operator button. [PLACE ONE DISC INTO SUPPLY BIN PRESS/
REL to GO] displays on the operator panel.
4. Place one disc into the supply bin.
Caution: Make sure that there is only one disc in the supply bin.
n
If you attempt to perform this test with more than one disc in the
system, miscalibration will occur. Miscalibration can cause damage
to the lift arm and recorders.
5. Press and release the operator button.
The lift arm moves to the supply bin and picks up the disc.
The lift arm releases the disc into the supply bin.
The lift arm moves back to its home position above the printer tray.
The Rimage 2000i exits diagnostic test mode and the system
restarts.
2002760_A
Access Diagnostic Test
For more information visit
Align the Printer on the Rimage 2000i
The printer is aligned at the factory. However, the printer can come out of
alignment during shipping. If the lift arm is not picking or placing discs on
the printer tray properly, or if you receive clamping errors, you need to align
the printer. Use the following procedure to align the printer.

# Required tools:

Torx T25 screwdriver
11/32" nut driver
5/32" Allen wrench
1. Stop or pause all jobs.
2. Make sure that the printer cables are connected.
3. Test the printer alignment.
a. Make sure the printer tray is closed.
b. Access diagnostic test mode. Refer to the
Mode
section on page 17.
c. Press the operator button four times and hold it in on the fourth
press. [JOG LIFT DIAGNOSTIC] displays on the operator panel. This
lift arm moves to the top of the lift column.
d. When [STARTING TEST RELEASE BUTTON] displays on the operator
panel, release the operator button.
e. Press
. The printer tray opens.