Herunterladen Inhalt Inhalt Diese Seite drucken

Oki LD630T Bedienungsanleitung Seite 30

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 126
5-8 Manual Calibration Mode
Manual-calibration of media detection can be used when the printer cannot detect a media
gap (or black mark) even after auto-calibration has been executed.
Users can calibrate sensor parameters in detail by using the utility program provided by
the manufacturer.
The utility can be obtained from the enclosed CD.
Please make sure the printer is connected and execute the utility program.
Click on the Calibration Setting Manager Button after setting the interface type.
1) Select the sensing type and input the label length by millimeter and click on "Check
Sensing Value" button. Then printer starts to calibrate.
2) Printer will print the scanned values after calibration and the values will appear on the
Screen.
3) Optimal sensing values will appear in bold letters on the left of the utility screen. Select
one of the optimal sensing value by clicking on it's option button and then click on "Save
Calibration."
4) If chosen value does not work properly, please try the other values among the bold
letters.
5) To go back to the initial value, please click on "Cancel Calibration"
Rev. 1.0
- 30 -
LD630T/LD640T

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ld640t

Inhaltsverzeichnis