TABLE 1
DIMENSIONS
MODEL
mm
(L x W)
70GLG40
400x730
70GLG80
800x730
70TGG40
400x730
70TGG80
800x730
80GLG40
400x900
80GLG80
800x900
80TGG40
400x900
80TGG80
800x900
90GLG45
450x900
90GLG90
900x900
TABLE 2
FOR SERIES 700s APPLIANCES
NOMINAL CAPACITY kW 9,3
Liquid gas
(G30 28...30mbar)
Natural gas
(G20 20mbar)
For appliances in series 730 (800x730x900) with nominal capacity 9,3 + 9,3 = 18,6 kW and reduced capacity
3,6 + 3,6 = 7,2 kW the injectors are double.
FOR APPLIANCES IN SERIES 900s
NOMINAL CAPACITY kW 12
Liquid gas
(G30 28...30mbar)
Natural gas
(G20 20mbar)
For appliances in series 900s (800/900x900x900) with nominal capacity 12 + 12 = 24 kW and reduced capacity
5 + 5 = 10 kW the injectors are double.

4. OPERATION WITH SUPPLY GAS IDENTICAL TO THAT AVAILABLE

Check whether the indications on the data plate correspond to the gas distributed. Also check correspondence to the
indications below.
4.1 Checking the supply pressure (Fig. 2)
The supply pressure can be measured by means of a pressure gauge with a
U-shaped pipe, or of the electronic type with a minimum grading of 0.1
mbar.
Unscrew the screw "A" from the pressure tap "B".
-
-
Position the pressure gauge.
Switch on the appliance and check that the pressure is the one
-
intended: otherwise check on the cause.
At the end of the operation, reassemble the appliance and check on the
-
connection.
ATTENTION: If the pressure measurement is not within the thresholds stated in table 3, instead of installing the
appliance you should contact your gas provider to report a fault with your mains supply.
Close the gas valve, disconnect the pressure measurement device, do up the screw you had previously undone and close
the front panel.
GAS
GAS
CAPACITY
COUPLING
kW
9,3
18,6
¾" Gc ISOR7
9,3
18,6
12
24
¾" Gc ISOR7
12
24
12
¾" Gc ISOR7
24
400x730x900H
REDUCED CAPACITY kW 3,6
Main burner
Pilot light injectors
injectors
Ø 1/100 mm
155*
215R*
400/450x900x900H
REDUCED CAPACITY kW 5
Main burner
Pilot light injectors
injectors
Ø 1/100 mm
165*
270R*
CONSUMPTION
RATE
Kg/h
0,733
1,467
0,733
1,467
0,946
1,893
0,946
1,893
0,946
1,893
By-pass
No.
Ø 1/100 mm
14*
90
27*
Adjustable
By-pass
No.
Ø 1/100 mm
14*
110
27*
Adjustable
9
CONSUMPTION
RATE
3
m
/h
0,984
1,968
0,984
1,968
1,270
2,540
1,270
2,540
1,270
2,540
Primary air pos.
main burner
(size in mm)
40
13
Primary air pos.
main burner
(size in mm)
40
13
A
B
Fig. 2
TYPE
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1