2.1 Installation of the appliance

The operations of installation, any conversion for use with other types of gas, start-up and the remedying of any faults in the
systems, must only be carried out by qualified staff, in accordance with current laws.
The gas systems and the rooms where the appliances are installed must fulfil the regulations existing in the various areas
and in particular consideration must be made of the fact that the air required for combustion of the burners is equal to 2 m
per kW of installed power and that accident prevention regulations must be observed.

2.2 Installation

Remove the appliances from the packing and position them in the place of use, levelling them and regulating their height by
means of the adjustable feet or other means.
Remove the protective film from the external panels, detaching it slowly to prevent the glue from remaining.
It is important that the walls adjacent to the appliance are protected against the heat. Place refractory sheets in between
them place the appliances at least 200 mm away from the side or rear walls.

2.3 Fumes extraction

The appliances must be installed in rooms suitable for the extraction of combustion products, in accordance with the
provisions of the installation instructions. Our equipment is considered (see specifications table) as:
"A1" TYPE GAS APPLIANCES
The A type appliances must be installed in sufficiently ventilated places in order to prevent the concentrations of harmful
substances in the room where the unit is installed. They are not designed to be connected to a discharge line of combustible
materials. These appliances must discharge the combustible products into the appropriate hoods, or similar devices,
connected to a flue of proven efficiency, or they may be connected directly to an outdoor vent.
Failing this, the use of an extractor fan is permitted, connected directly to an external area, with sufficient capacity, which will
then be increased by the exchange of air necessary for the welfare of the workers under current regulations, approximately
35 m³/h for each kW of gas power installed.

2.4 Connecting up gas

Check on the rating plate (Fig. 1), under the fires on the left-hand side, that the appliance has been tested and approved for
the type of gas that the user uses.
Check that the nozzeles on the appliance are suitable for the available gas supply.
Check on the rating plate that the pressure reducer is adeguate to the appliance's gas supply
If gas supply pressure deviates by more than 10% from nominal pressure, fit a pressure regulator upstream of the appliance
to ensure that nominal pressure is maintained.
Do not reduce the diameter of the pipe between the reducer and the appliance.
Fit a gas filter upstream of the pressure regulator in order to optimise operating efficiency.
The data plate is located on the left of the cabinet.
-
Appliance in category
-
Supply pressure: Butane/Propane (G30-G31) 30/37mbar
2. INSTALLATION

3. TECHNICAL FEATURES

Natural gas (G20) 20mbar
8