5 ELECTRICAL CONNECTIONS

Execute the wiring following the directions of "Table 1" and diagrams on page 26.
WARNING For adequate electrical safety, keep low safety voltage wires (controls, electro-locks, antenna, auxiliary power) clearly separate
from 230V ~ power wires (minimum 4 mm in air or 1 mm via supplementary insulation) placing them in plastic raceways and securing
them with adequate clamps near terminal boards.
WARNING For connection to the mains, use a multipolar cable having a minimum section 3x1,5 mm² and complying with the current
regulations. For connecting the motors, use a minimum cross section 1,5 mm² cable and complying with the current regulations. As
an example, if the cable is out side (outdoor), must be at least equal to H05RN-F, whereas if it (in a raceway), must be at least equal to
H05VV-F.
WARNING All wires must be striped and unsheathed in the immediate vicinity of terminals. Keep wires slightly longer to subsequently
eliminate any excess.
WARNING To connect the encoder to the control panel, use only a dedicated cable 3x0,22mm
1
Unused
2-3-4
Motor 1 encoder output
5-6
Motor 1 output max 5A
7 (+)
7-8
24 V
8 (-)
9 - N.C.
9-13
Input 4 FCC 1. If it intervenes it stops M1 closing. If unused, short circuit.
13 - Com
10 - N.C.
10-13
Input 3 FCA 1. If it intervenes it stops M1 opening. If unused, short circuit.
13 - Com
Input 2 PHOTO 1. When enabled (see parameter P050 in the table), activation of
11 - N.C.
11-13
PHOTO 1 provokes: an inversion of direction (during closing), the arrest of the move-
ment (during opening), prevent the start (gate closed). If unused, short circuit.
13 - Com
12 - N.O.
Input 1 START. In case of intervention it provokes: the operator opening or closing. It
12-13
may operate as "inversion" mode (P049=0) or "step by step" mode (P049=1).
13 - Com
14 (-)
14-15
Stabilized 24 V
15 (+)
16 (+)
24 V
16-17
(if P052>1)
17 (-)
18
Aerial signal input
Ground aerial input
19
CON 1
Connection of motors metallic parts
CON 2
22 V ~ transformer power supply input
CON 3
Input for MEMONET connector
Table 1 "terminal board connections"
Flashing light output max 5W
auxiliary power supply output max 200mA
max 5W output for open gate fix warning light (if P052=0), flashing (if P052=1) or courtesy light
.