Herunterladen Inhalt Inhalt Diese Seite drucken

Installation Advice - BEMKO SES12-A Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Good sensitivity

INSTALLATION ADVICE:

As the detector responds to changes in temperature, avoid the following situations:
Avoid pointing the detector towards objects with highly reflective surfaces, such as mirrors
etc.
Avoid mounting the detector near heat sources, such as heating vents, air conditioning
units, light etc.
Avoid pointing the detector towards objects that may move in the wind, such as curtains, tall
plants etc.
CONNECTION:
Warning. Danger of death through electric shock!
Must be installed by professional electrician.
Disconnect power source.
Cover or shied any adjacent live components.
Ensure device cannot be switched on.
Check power supply is disconnected.
Loosen the screw in the back and unload the bottom (refer to figure 1).
Find the wire hole with gasket in the downside of the sensor and pass the power wire
through hole. Connect the power wire into connection-wire column according to the
connection-wire diagram.
Fix the bottom with inflated screw on the selected position. (refer to figure 2)
Install back the sensor on the bottom, tighten the screw and then test it.
Figure1
Poor sensitivity
Figure2
CONNECTION-WIRE DIAGRAM:
(See the right figure)
TEST:
Turn the TIME knob anti-clockwise on the minimum (10s). Turn the LUX knob clockwise
on the maximum (sun).
Switch on the power; the sensor and its
connected lamp will have no signal at the
beginning. After Warm-up 30sec, the sensor
can start work .If the sensor receives the
induction signal, the lamp will turn on. While
there is no another induction signal any more,
the load should stop working within 10sec±3sec and the lamp would turn off.
Turn LUX knob anti-clockwise on the minimum (3). If the ambient light is more than 3LUX,
the sensor would not work and the lamp stop working too. If the ambient light is less than
3LUX (darkness), the sensor would work. Under no induction signal condition, the sensor
should stop working within 10sec±3sec.
Note: when testing in daylight, please turn LUX knob to
the sensor lamp could not work!
SOME PROBLEM AND SOLVED WAY:
The load does not work:
a. Please check if the connection of power source and load is correct.
b. Please check if the load is good.
c. Please check if the settings of working light correspond to ambient light.
The sensitivity is poor:
a. Please check if there is any hindrance in front of the detector to affect it to receive
the signals.
b. Please check if the ambient temperature is too high.
c. Please check if the induction signal source is in the detection field.
d. Please check if the installation height corresponds to the height required in the
instruction.
(SUN) position, otherwise

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis