LAVA STONE GRILLS

TROUBLESHOOTING

The purpose of the following information is to help the operator to identify and correct any
anomalies or malfunctions that may occur during use.
Some faults may be resolved by the user, others require specific technical skills or abilities
and must only be performed by qualified personnel with recognised experience in the spe-
cific sector.
Important
Do not remove internal appliance parts.
The manufacturer is not liable for any machine tampering!
Table 2: Operating malfunctions
Problem
Gas odour
The pilot flame does not ignite
The pilot flame does not remain on

GAS CONNECTION

– All the gas connection, transformation and pressure control operations must be per-
formed by authorised personnel who must have specific technical skills and special abil-
ities in the specific sector. This also applies for all extraordinary maintenance operations
such as lubrication and/or faucet replacement and thermocouple or burner replacement.
– Equip the appliance gas supply tube with a faucet to be able to cut of gas supply in the
event of need.
– The faucet (not supplied with the appliance) must be installed in a visible and accessible
position in order to easily identify its operating status (open or closed).

GAS SUPPLY TRANSFORMATION

The appliance is marketed with indications of the gas mains used by the manufacturer for
inspections.
If the gas mains do not correspond to the one used for inspection, before connecting the
gas mains, the installation technician must "transform" the appliance and indicate the type
of gas in use on the plate.
Important
After "transforming" the appliance to the gas mains in use, make sure there are no
gas leaks or operating defects, test the appliance and indicate the type of gas in use
on the identification plate.
Causes
Temporary leak when flame is
extinguished.
The piezoelectric switch does not
work
The thermocouple is not sufficiently
heated
- 11 -
GL33 - GL66
Solutions
Close the supply faucet and ventilate
the room
Check piezoelectric switch efficiency
and, if necessary, manually ignite
with a free flame
If the problem persists, contact your
dealer or authorised service centre
Insist with the ignition operation
longer