GENERAL OPERATION
1. Turn MAIN POWER SWITCH to "ON".
LIFTING AND LOWERING BRIDGE
WARNING- Insure FAUCET SPOUT is out of way before raising or lowering bridge.
1. Turn MIX/LIFT SWITCH to "LIFT".
2. Turn MIXER SPEED CONTROL to "MIN" and back up to #5.
3. Turn and hold UP/DOWN SWITCH UP" to raise or "DOWN" to lower.
MIXING
1. Turn MIX/LIFT SWITCH to "MIX".
2. Turn MIXER SPEED CONTROL to "MIN" and slowly adjust to desired speed.
3. Adjust SECONDARY SPEED CONTROL to desired speed. .
TILTING KETTLE
1. Raise MIXER BRIDGE (6) and swing to side.
2. For manual tilt: turn HANDWHEEL.
3. For power tilt: turn switch POWER TILT CONTROL SWITCH to raise, or to tilt.
WARNING- Do not tilt kettle when mixer agitators are in kettle bowl.
ADDING WATER MANUALLY
1. Locate FAUCET SPOUT over desired kettle.
2. Turn on HOT or COLD WATER VALVES.
DISCHARGE VALVE
1. For air valve: turn Air Regulator clockwise to open, or counterclockwise to close.
2. For butterfly valve: push handle in and pull upwards to open.
MANUAL HEATING/COOLING
1. Turn ACTIVE/BYPASS SWITCH to "BYPASS".
2. Turn CONTROLLER SWITCH to "HEAT" or "COOL".
3. For heat: open steam valve completely to boil, or adjust to regulate temperature.
For cooling: open steam valve completely.