9.

Programming hints

single-user vs. multi-user mode
In single-user mode every output can be controlled by only one 4-digit
user code. User codes are stored in memory location
the
-confirmation is not required after entering the user code (auto-
entry mode).
In multi-user mode, up to 100 user codes can be assigned to control
output 1 and up to 10 to control output 2. These user codes can consist
of 4 to 8 digits and the
entering the code (manual entry mode). Before setting to auto-entry
mode, all user codes must have the same length as the master code
(between 4 and 8 digits).
Duress code
User code 1 in single-user mode and all user codes of group 1 in multi-
user mode come with a duress code function. This duress code is
automatically created by adding 2 to the first digit of the user code. E.g.
when the user code is 56789, the duress code becomes 76789.
When a user enters the duress code in stead of the normal user code, the
DU-OUT terminal [f] is switched to ground and can be used to trigger a
(silent) alarm.
User code limitations
To avoid overlapping of valid user codes and duress codes, and since the
duress code is based on the first digit of the user codes, it is not allowed
to have user codes that only differ by +2 or -2 in the first digit.
Example: if a user code 56789 exists in the system, user codes 36789
and 76789 will be refused by the system when trying to set them as
other user codes.
Accelerated code
The accelerated code consists of the first two digits of the user code(s).
When enabled (programming code 42 or 52) the user can activate the
output(s) by entering only the first 2 digits of his user code. To deactivate
the output the full user code is always required.
Deleting a user code in multi-user mode
Enter programming mode using the master code and the
Enter the group number (1 or 2) followed by the user code (0~99 for
group 1 user, 0~9 for a group 2 member) that needs to be deleted
Confirm with the
Resetting the system
When switching between single-user and multi user mode the keypad is
completely reset and all values are set back to factory default except for
the master code.