2.9 Problem sources and their solving
In case of failures (e.g. smoke) appearing during operation, contact your local competent chimney sweeper. If damage is
caused to the fireplace, contact the shop where you purchased the fireplace. These are the most common failures, their
sources and solutions:
Type of failure
Possible cause
Smell creating
Used protective paint drying
out, evaporation of oil
residues.
Too low thermal
Selected power is too small.
power
Insufficient chimney blast.
Smoke tube is incorrectly
connected.
Fireplace reeks
Smoke is insufficiently drawn
and smokes
away (obstructed chimney or
return flow in chimney).
Chimney is too weak.
Combustion of wet wood.
Glass in stoker
Incorrect combustion, e.g.
door gets
wet wood.
quickly dirty with
Smoke is insufficiently drawn
soot
away (obstructed chimney or
return flow in chimney).
Fireplace heats
Sealing of stoker door is
too strong
damaged.
Curl of smoke,
Sometimes obstructed
puff of smoke
chimney or return flow in
chimney.
When all air suppliers are
closed.
Too much fuel in hearth.
Damage to grate
Grate is burnt through, or
scaled.
2.10 Accessories list
-
protective glove
-
manipulating handle
2.11 Spare parts list
-
stoker door
-
stoker door glass
-
stoker door gasket
-
stoker door handle
-
vermiculittes set
-
ash box
-
cast-iron grate
- steel grate for saving of glass
Only use these spare parts.
3.
Warranty
If a failure of function or failure of surface coating appears during the warranty period, never repair it yourself. Warranty and
after-warranty repairs are performed by the manufacturer.
We guarantee for the quality, function and elaboration of the fireplace for the period of 2 years from the date of purchase by
customer, in terms that all failures undoubtedly caused by incorrect manufacturing we repair in short time at our own expense,
under the condition that the fireplace:
- was operated exactly according to the manual
- was connected to the chimney according to the standards
Solution
Operate the fireplace according to the operation manual for few
hours at low power. Then heat for few hours at maximum power.
Let the heat necessity be checked by an expert.
Chimney blast must be at least 12 Pa! Check the chimney for
tightness. Doors of other devices connected to the chimney must be
closed tight. Ensure tightness of cleaning covers. Possibly use 1,5 m
long vertical smoke tube (slope path).
Check the smoke tube.
The cause is nearly always in the area of combustion gases route.
Check the smoke tubes and chimney blast, if possible, consult a
chimney sweeper.
Only use well dried wood.
Only use well dried wood.
Check the smoke tubes and chimney blast, if possible, consult a
chimney sweeper.
Change the seal.
Consult a chimney sweeper.
During operation, all air suppliers cannot be closed.
Only add one layer.
Burning of grate is always caused by full ash box. Empty ash box.
5