Herunterladen Diese Seite drucken

Troubleshooting - Omron BF214 Gebrauchsanweisung

Körperanalyse monitor
Vorschau ausblenden Andere Handbücher für BF214:

Werbung

12
Please read this instruction manual carefully before use and for further information on the
individual functions.
(1) Medical electronic implants such as pacemakers.
(3) Portable electronic medical devices such as electrocardiograph.
considerable health risk to users of these devices.
to follow the instructions of a doctor or specialist.
Use a handrail or so when stepping on the unit.
other medical facilities.

Troubleshooting

Possible cause
You step off the unit during the measurement.
Your feet are not correctly positioned on the electrodes.
The measurement position is not stable or your feet are not
placed correctly.
Feet are too dry.
The unit is not set up correctly.
You step onto the unit before 0.0 kg (0.0 lb) is displayed.
The unit moved before 0.0 kg (0.0 lb) is displayed.
Movement during measurement.
Your weight is over 150.0 kg (330.0 lb or 23 st 8.0 lb).
Technical Data
Product description
Body Composition Monitor
Product name
BF214
Model
HBF-214-EBW
Display
Body Weight: 2 to 150 kg with an increment of 0.1 kg / 4.4 to 330.0 lb with an increment of 0.2 lb / 4.4 lb to 23 st 8.0 lb with an increment of 0.2 lb
Body Fat percentage: 5.0 to 60.0% with an increment of 0.1%
Skeletal Muscle percentage: 5.0 to 50.0% with an increment of 0.1%
BMI: 7.0 to 90.0 with an increment of 0.1
Memory:
Last (previous) measurement results
Set Items Personal data information:
The following information for up to 4 people can be stored.
Height: 100.0 to 199.5 cm , 3'4" to 6'6 3/4" (increment of 1/4")
Age: 10 to 80 years old
Gender: Male/Female
Weight Accuracy
2.0 kg to 40.0 kg: ± 0.4 kg, 40.0 kg to 150.0 kg: ± 1% / 4.4 lb to 88.2 lb: ± 0.88 lb, 88.2 lb to 330.0 lb: ± 1% / 4.4 lb to 6 st 4.2 lb: ± 0.88 lb, 6 st 4.2 lb to 23 st 8.0 lb: ± 1%
Accuracy (S.E.E.)
Body Fat percentage: 3.5%, Skeletal Muscle percentage: 3.5%
Durable Period
5 years
Power Supply
4 AAA batteries (R03) (You may also use AAA alkaline batteries (LR03).)
Battery Life
Approximately one year (When AAA manganese batteries are used with four measurements a day at a room temperature of 23°C.)
Storage Temperature / Humidity / Air Pressure
-20 to 60°C / 10 to 95% RH / 700 to 1060 hPa
Weight
Approximately 1.6 kg (including batteries)
External Dimensions
Approximately 285 (W) × 28 (H) × 280 (D) mm
Package Contents
Body composition monitor, 4 AAA manganese batteries (R03), instruction manual
OMRON HEALTHCARE EUROPE B.V. guarantees this product for 3 years after date of purchase.
The guarantee does not cover battery, packaging and/or damages of any kind due to misusage (such as dropping or physical misuse) caused by the user. Claimed products will only be replaced when returned together with
the original invoice / cash ticket.
With the increased number of electronic devices such as PC's and mobile (cellular) telephones,
medical devices in use may be susceptible to electromagnetic interference from other devices.
Electromagnetic interference may result in incorrect operation of the medical device and create a
potentially unsafe situation.
Medical devices should also not interfere with other devices.
In order to regulate the requirements for EMC (Electro Magnetic Compatibility) with the aim to
prevent unsafe product situations, the EN60601-1-2:2007 standard has been implemented. This
levels of electromagnetic emissions for medical devices.
This medical device manufactured by OMRON HEALTHCARE conforms to this EN60601-1-2:2007
standard for both immunity and emissions.Nevertheless, special precautions need to be observed:
and create a potentially unsafe situation. Recommendation is to keep a minimum distance of 7 m.
12
the wrong direction.
(approximately three months or more).
hazard if swallowed by infants.
measurement may not be possible.
national regulations for the disposal of electronic products.
- Where water may get in.
- Extreme high temperature and humidity, direct sunshine, and dusty places.
- Where there will be sudden shock or vibration.
- In storage places of chemicals or where corrosive gas is present.
Correction
Do not step off the unit till the measurement is completed.
Make sure that you are standing on the unit correctly and try again.
Remain still and do not move during measurement.
Slightly moisten the soles of your feet with a damp towel and try again.
Remove the batteries. Wait one minute. Reinstall the batteries. Touch the ON-OFF-SET button and turn on the
power. Retake the measurement.
Wait until 0.0 kg (0.0 lb) is displayed before stepping onto the unit.
Do not move the unit until 0.0 kg (0.0 lb) is displayed
Do not move till measurement is completed.
This unit can only be used by people weighing less than 150.0 kg (330.0 lb or 23 st 8.0 lb).
= Type BF
Verify correct operation of the device in case the distance is shorter.
Further documentation in accordance with EN60601-1-2:2007 is avail-able at OMRON
HEALTHCARE EUROPE at the address mentioned in this instruction manual.Documentation is
also available at www.omron-healthcare.com.
This marking shown on the product or its literature, indicates that it should not be
disposed of, with other household wastes at the end of its working life. To prevent
possible harm to the environment or human health from uncontrolled waste disposal,
please separate this product from other types of wastes and recycle it responsibly to
promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their
safe recycling.
Business users should contact their supplier and check the terms and conditions of the purchase
contract. This product should not be mixed with other commercial wastes for disposal.

Werbung

loading