If you are cabling more than one disk enclosure,
refer to the HPE StoreOnce 5500 System Capacity
Upgrade Guide before proceeding.
1.
Connect the supplied 0.5 m mini-SAS cables
as follows:
Drawer 2, I/O module A, port 1 to Drawer
1, I/O module A, port 2
Drawer 2, I/O module B, port 1 to Drawer
1, I/O module B, port 2
IOM A
IOM B
D2
2.
Connect the supplied 2 m HD SAS cables from
the RAID controller card in slot 2 of the head
server unit to the first disk enclosure as follows:
RAID card in PCI slot 2, port 1 to Drawer
1, I/O module A, port 1
RAID card in PCI slot 2, port 2 to Drawer
2, I/O module B, port 2
IOM A
IOM B
D2
P2
P1
1
2
3
4
1
Step 6: Connect power cables
For resiliency purposes connect each
TIP:
power cord to a separate PDU within the rack
if available.
IOM A
P2
P2
P1
P1
IOM B
P2
P2
P1
P1
D1
IOM A
P2
P2
P1
P1
IOM B
P2
P2
P1
P1
D1
4
5
PS1
PS2
6
iLO
1
4
There are:
Four power sockets on each disk enclosure;
two to each drawer.
Two power sockets on the head server unit
Step 7: Connect keyboard and monitor
1
Step 8: Connect LAN port 1
Connect LAN port 1 to the 1GbE network that will
be used to manage the StoreOnce System.
Page 5
2