Herunterladen Inhalt Inhalt Diese Seite drucken

Victron energy MPPT 100/30 Anleitung Seite 9

Vorschau ausblenden Andere Handbücher für MPPT 100/30:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 49
3.5 Configuration of the controller
Fully programmable charge algorithm (see the software page on
our website) and eight preprogrammed charge algorithms,
selectable with a rotary switch:
Pos
Suggested battery type
Gel Victron long life (OPzV)
0
Gel exide A600 (OPzV)
Gel MK
Gel Victron deep discharge
1
Gel Exide A200
AGM Victron deep discharge
Stationary tubular plate (OPzS)
Default setting
Gel Victron deep discharge
2
Gel Exide A200
AGM Victron deep discharge
Stationary tubular plate (OPzS)
AGM spiral cell
3
Stationary tubular plate (OPzS)
Rolls AGM
PzS tubular plate traction
4
batteries or
OPzS batteries
PzS tubular plate traction
5
batteries or
OPzS batteries
PzS tubular plate traction
6
batteries or
OPzS batteries
Lithium Iron Phosphate
7
(LiFePo
) batteries
4
Note 1: divide all values by two in case of a 12V system.
Note 2: equalize normally off, see sect. 3.8.1 to activate
(do not equalize VRLA Gel and AGM batteries)
Note 3: any setting change performed with Bluetooth or via VE.Direct will
override the rotary switch setting. Turning the rotary switch will override prior
settings made with Bluetooth or VE.Direct.
Absorption
V
28,2
28,6
28,8
29,4
29,8
30,2
30,6
28,4
7
Float
Equalize
V
V
@%I
nom
31,8
27,6
@8%
32,2
27,6
@8%
32,4
27,6
@8%
33,0
27,6
@8%
33,4
27,6
@25%
33,8
27,6
@25%
34,2
27,6
@25%
27,0
n.a.
dV/dT
mV/°C
-32
-32
-32
-32
-32
-32
-32
0

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading