3) ROGER BEEP

When the function is active, the icon
The Roger Beep sounds when the PTT switch (11) on the microphone is released in order to let
your correspondent speak. Historically as transceiver is a "simplex" communication mode, it is
not possible to speak and to listen at the same time (as it is the case with a telephone). Once
someone had fi nished talking, he said "Roger" in order to prevent his correspondent that it was
his turn to talk. The word "Roger" has been replaced by a signifi cant beep. There comes "Roger
beep" from.
1.
Turn on the power while pressing the UP button (12) on the microphone. The display shows "
and the current status on the function: OF or On.
2.
Repeat the point 1 until the display shows the desired status.
3.
Release the UP key on the microphone.
When the function is activated "BP" appears on the display.
Default ROGER BEEP is OF.

4) FREQUENCY BAND SELECTION

(Confi guration: EU; PL; d; EC; U; In)
The frequency bands have to be chosen according to the country of use. Don't use any other
confi guration. Some countries need a user's licence. See table page <?>.
1.
Turn on the power while pressing the F key (7). The letter corresponding to the current confi gura-
tion is blinking.
2.
In order to change the confi guration, use the ROTARY knob (4) on the unit or the UP/DN buttons
(12) on the microphone.
3.
When the confi guration is selected, press the F key (7) during 1 second. The letter corresponding
to the confi guration is continuously displayed and a confi rmation beep sounds.
4.
At this point, confi rm the selection by switching off the transceiver and then switching it on again.
See the frequency bands table at pages 49 to 51 / confi guration table page 48.
5) RESET
Resets all user-defi ned settings and returns to default values.
1.
Turn on the power while pressing the EMG key (6). "
2.
Long press F knob (7) to reset. A long beep confi rms that the re-initialization have been done.
3.
If no key is pressed for 5 seconds or if the PTT switch (11) is pressed, the unit exits RESET without
change.
D) TECHNICAL CHARACTERISTICS
1) GENERAL
- Channels
- Modulation modes
- Frequency ranges
- Antenna impedance
- Power supply
- Dimensions
- Weight
- Accessories supplied
2)
TRANSMISSION
- Frequency allowance
- Carrier power
- Transmission interference
- Audio response
- Emitted power in the adj. channel : inferior to 20 µW
- Microphone sensitivity
- Drain
- Modulated signal distortion
appears on the display.
" blinks on the display.
: 40 (80)
: AM / FM
: from 26.565 MHz to 27.99125 MHz
: 50 ohms
: 13.2 / 24,6 V
: 125 (L) x 150 (P) x 45 (H) mm
: ± 0.7 kg
: 1 microphone electret UP/DOWN with
support, mounting cradle, screws and
fused power cord.
: +/- 200 Hz
: 4 W AM / 4 W FM
: inferior to 4 nW (- 54 dBm)
: 300 Hz to 3 KHz in AM/FM
: 5 mV
: < 1.7 A max. (with modulation)
: 1,8 %