Herunterladen Inhalt Inhalt Diese Seite drucken

Cleaning Of The Unit; Specifications - IMG STAGELINE LSE-150RG Bedienungsanleitung

Dmx-laser-effektgerät
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
1) Press the button FUNC (15) so many times until
a number between 1 and 512 flashes on the dis-
play (9) [also see fig. 4]. The number is the DMX
start address.
2) Adjust the desired address with the button UP or
DOWN.
3) Memorize the address with the button ENTER.
As soon as the LSE-150RG receives the DMX
signals of the controller, the DMX address stops
flashing on the display. The laser can now be
operated via the DMX controller. To make the
laser beams visible, adjust the DMX channel 1 to
a DMX value higher than 9. From a value of 161
or higher, additionally adjust the DMX channel 7
to a value higher than 36 (

7 Cleaning of the Unit

The optical elements (mirror, scatter panes) should
be cleaned at regular intervals, depending on impu-
rities caused by dust, smoke, or other particles.
Only in this case the laser beam can be radiated at
maximum brightness.
WARNING As the unit has to be opened for
cleaning, this must only be carried
out by expert personnel! Prior to
opening, disconnect the mains plug
from the socket.
Only use a soft, clean cloth and a detergent for
glass. Then carefully wipe the elements dry.
For cleaning the other parts of the housing only
use a soft, clean cloth. Never use any fluid, it could
penetrate the unit and cause damage.

8 Specifications

Laser wavelength / power
green laser: . . . . . 532 nm / 40 mW
red laser: . . . . . . . 650 nm / 100 mW
Laser class: . . . . . . . 3b
Power supply: . . . . . 230 V~ / 50 Hz
Power consumption: 25 VA max.
Ambient temperature: 10 – 40 °C
Dimensions: . . . . . . . 255 × 145 × 210 mm
Weight: . . . . . . . . . . . 2.2 kg
Hint: The laser diodes are subject to extreme stress due to
the high lighting power and therefore only have a limited life-
time. As in case of all wear parts, no warranty claim for the
laser diodes will be accepted.
All rights reserved by MONACOR
may be reproduced in any form or by any means for any commercial use.
table on the right).
INTERNATIONAL GmbH & Co. KG. No part of this instruction manual
®
8.1 Functions of the DMX channels
DMX Value
Function
Channel 1: Operating mode
000 – 009
laser turned off
show programme with random sequence of
010 – 060
patterns
061 – 110
show programme slowly running
111 – 160
show programme, music-controlled
161 – 255
DMX control via the channels 2 – 8
Channel 2: Laser pattern
000 – 025
scatter pattern 1
026 – 050
scatter pattern 2
051 – 075
scatter pattern 3
076 – 100
scatter pattern 4
101 – 125
scatter pattern 5
126 – 150
scatter pattern 6
151 – 175
scatter pattern 7
176 – 200
scatter pattern 8
201 – 225
scatter pattern 9
226 – 255
scatter pattern 10
Channel 3: Vibration
slow → fast
000 – 255
Channel 4: Second light scattering
nd
000 – 127
2
scattering off
128 – 255
2
nd
scattering on
Channel 5: Rotation of the 2
slow → fast
000 – 255
Channel 6: Rotating angle of the 2
small → large
000 – 255
Channel 7: Colour
000 – 036
laser beams turned off
037 – 072
red laser beams only
073 – 108
green laser beams only
109 – 144
red and green laser beams alternately*
145 – 180
red beams on, green beams with stroboscope*
181 – 216
green beams on, red beams with stroboscope*
217 – 218
red and green laser beams
Channel 8: Stroboscope
000 – 009
no stroboscope
slow → fast
010 – 255
* If the stroboscope function is switched off by the DMX
channel 8, the red and green beams light up continuously
with these DMX values.
Subject to technical modification.
nd
light scattering
nd
light scattering
GB
11

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis