ELECTRONIC CONTROL PANEL
If the regeneration is initiated on a given day, the
message „REGENERATION TODAY" appears on the
screen.
REGENERATION MODE
The system is configured in such way that it goes into the
regeneration mode when the water demand is lower
(night hours).
The regeneration process starts automatically, and then it
resets to the water treatment mode by itself. When the
regeneration is completed, the system starts again to
supply the installation with the treated water.
REGENERATION MODE
MANUAL REGENERATION: Sometimes it is necessary to
initiate the earlier cycle of regeneration. It may be related
to an intensive period of the system exploitation.

MAINTENANCE

ROUTINE CHECKS
Regularly the user should perform a basic check to verify
if the appliance is functioning correctly, on the basis
of the following control points:
1. Check settings of electronic control panel.
2. Measure the contamination level before and behind
the appliance.
3. Check drain line from control valve; there
shouldn't be any water flow (unless appliance
is in regeneration).
4. Check appliance and surrounding area; there
shouldn't be any water leakages.
BYPASSING THE APPLIANCE
Occasionally it may be necessary to put the appliance
hydraulically in bypass, i.e. to isolate it from the water
distribution system; f.e.:
- in case of an urgent technical problem;
- when it is not necessary to supply treated water
to the house/application (refill swimming pool,
irrigation,...).
POSTPONED MODE: To initiate the regeneration manually
and define its time, you should press and release the
button „REGEN". „REGENERATION TODAY" appears on the
screen, the system goes into the regeneration mode at the
set time (you can change the time of regeneration by
reprogramming the hour according to the steps described
previously).
If pressing the button „REGEN" causes an error display,
pressing it again will cancel the whole procedure.
INSTANT MODE: To initiate the regeneration immediately,
you should press and hold the button „REGEN". The
system immediately goes into the regeneration mode.
NOTE! THIS PROCESS CANNOT BE CANCELLED.
In case the system is during the regeneration, it is possible
to supply the installation with untreated water. In such
situation you should set the BY-PASS valve in the BYPASS
POSITION.
WITH FACTORY BYPASS (optional).
[1]
2
OFF
SERVICE POSITION [1]
1. inlet valve to appliance is OPEN.
2. outlet valve from appliance is OPEN.
1
OFF
15