Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

ELECTRONIC CONTROL PANEL
Step 2: SETTING THE LANGUAGE - the display shows that it
operates in English version „ENGLISH". With the buttons
„+" or „-" you can change the language. The user may
select the following language versions: English, German,
French, Spanish and Italian. Press the button „REGEN" if
you want to finish, or „NEXT" if you want to go to the next
parameter.
ENGLISH
DISPLAY
SET
SET CLOCK
REGEN
Step 3: Setting the time regeneration - As standard the
producer set the interval between the regenerations
every 4 days. If this parameter is set as „OFF", the
regeneration will take place in the volume mode i.e. it will
be initiated when proper amount of water in m3 has flown
through the system.
If the daily regeneration mode is set at the position „OFF",
then the system will operate in the volume mode, but if
the time regeneration parameter is set up (range 1 - 28),
then the system will operate in the volume and time
mode.
With the buttons „+" or „-" set the daily regeneration
mode (recommended 4 days).
NOTE! Based on the observation and the result of the
water test done, the user may increase the time interval
between the regenerations. In order to adjust the
appliance as precisely as possible to the flushing cycles,
we suggest also using the readouts from the pressure
gauges installed on the water inlet and outlet from the
appliance. The difference in the values, (the pressure
drop at the second pressure gauge by 0.5 bars or more),
informs when the next regeneration of the appliance
should occur.
Press the button „NEXT" to go to the next parameter. Press
the button „REGEN" if you want to go back to the previous
parameter.
DAYS BETWEEN REGEN
SET
SET CLOCK
REGEN
12
+
-
NEXT
+
6
-
NEXT
Step 4: Setting the regeneration time (HOUR) - As standard
the producer set the regeneration at 2:00. At that time the
appliance regeneration cycles are to be initiated. By
means of the buttons „+" or „-" you can set by yourself the
time at which the system is to initiate the regeneration
process. We suggest to leave the regeneration time in the
standard mode, because the water demand is smaller at
night, and in most cases the electricity cost tariff is lower.
Press the button „NEXT", to go to the next parameter.
Press the button „REGEN" if you want to go back to the
previous parameter.
REGEN TIME HOUR
2:00
SET
SET CLOCK
REGEN
Step 5: Setting the regeneration time (MINUTES) - By
pressing the buttons „+" or „-", set the minutes
analogically.
Press the button „NEXT" to go to the next parameter. Press
the button „REGEN", if you want to go back to the previous
parameter.
SERVICE ALARM
OFF
SET
SET CLOCK
REGEN
Step 6A: Service alarm - By pressing the buttons „+" or „-"
3
set the service alarm in m .
If you want your appliance to remind you about the
planned service works after the proper amount of water
has flown through, switch on the service message (range
3
100 - 50000 m ). The producer recommends to leave this
option as switched off - OFF mode.
+
-
NEXT
+
3
m
-
NEXT

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Oxyline plus

Inhaltsverzeichnis