On/Off button:
Press this button to start or stop the pump
When the pump is stopped, the display indicates a rotation speed of 0rpm
If the pump is stopped on purpose or during an unexpected power cut, the pump will start at the maximum speed of
3,000rpm during the configured priming time and will then return to the last speed selected before the shutdown or power
cut.
Power on indicator:
The blue indicator lights up when the power to the pump is on
Settings scroll button:
In normal operating mode, the digital display gives the rotation speed
Pressing the DISP/FUNC button once displays the instantaneous power consumed in Watts to +/- 10%. The power
display is preceded by the letter P: E.g. P500.
Pressing the DISP/FUNC button a second time will display the total number of operating hours for the pump up to 10,000
hours. The number of hours display is preceded by the letter h: E.g. h10,000.
Pressing the DISP/FUNC button a third time will display the preselected priming time in seconds. The priming time display
is preceded by the letter Pr: E.g. Pr60 for a 60-second priming time.
Pressing the DISP/FUNC button a fourth time gives access to the pump reset function. INIT appears on the display.
Pressing the DISP/FUNC button a fifth time displays the version of the electronic driver. Display of the version is
preceded by the letters Id: E.g. Id 100.
Pressing the DISP/FUNC button a sixth time displays the temperature of the electronic power module. The temperature
display is preceded by the letter t: E.g. t 85°C
Factory-set speed:
Buttons V1, V2 and V3 are used to select one of the three factory-set speeds.
The factory-set speeds are:
The blue LED indicates that the speed has been correctly selected.
Up and Down buttons:
The Up/Down buttons are used to increase or decrease the rotation speed when the pump is operating. If the pump is in
default settings reset mode, pressing the Up and Down buttons once confirms the reset.
Hayward variable speed pumps
®
use factory-set rotation speeds. To select a speed, ensure that the pump is switched on
and press the speed of your choice. The blue indicator lights up to indicate that the selection has been recognised. Then
press the On/Off button to start the pump.
default factory setting) before automatically returning to the selected rotation speed or the speed previously selected.
It is also possible to set rotation speeds other than those preset in the factory in the range 600rmp to 3,000rpm.
scrolling.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 6 of 8
Pump
Rev. C