PRE-START UP PROCEDURE

Before operating your EcoSalt2 salt pool chlorination system, please ensure the following quantity of pool
salt has been added to your pool.
• POOL SALT:
To raise salt
concentration by
30,000L 40,000L 50,000L 60,000L 70,000L
ppm
%
kg
lbs
1,000
0.1
30
2,000
0.2
60
132 80
3,000
0.3
90
198 120 265 150 331 180 397 210 463 240
4,000
0.4
120 265 160 353 200 441 240 529 280 617 320
5,000
0.5
150 331 200 441 250 551 300 661 350 772 400
6,000
0.6
180 397 240 529 300 661 360 794 420 926 480 1,058 540 1,190 600 1,323
• CHLORINE: For a new pool installation that has not been chlorinated, add sufficient Chlorine (liquid or
granular) to achieve a reading of 3 ppm (with a suitable test kit). Alternatively, run the EcoSalt2 salt pool
chlorination system continuously on BOOST MODE, for approximately 24 hours, or until a reading of 3 ppm
is reached.
• STABILISER: It is essential that pool stabiliser be added and maintained at the rate of 25 - 50 ppm at
all times (FOR OUTDOOR POOLS ONLY). For ORP controlled systems the stabiliser level should be
maintained between 15-25ppm.
• (Refer Day to Day Operation page 27 for further information).

OPERATION OF YOUR EcoSalt2

CHLORINE OUTPUT is expressed as a percentage. Set the EcoSalt2 to the percentage output required
and the unit will automatically adjust the cell output to the set level. The EcoSalt2 is fitted with an electronic
control and warning system. This regulates the output of the EcoSalt2 to the pre-set maximum and changes
cell polarity as indicated by the + or – on the digital display. The polarity will alternate over a number of
hours of chlorination time, not necessarily pump-run hours. The warning system consists of one Operation
LED which will glow Green to indicate normal operation, or RED to indicate user attention required, see
troubleshooting on page 21.
kg
lbs
kg
lbs
66
40
88
50
110 60
176 100 220 120 265 140 309 160
Salt required
80,000L
kg
lbs
kg
lbs
kg
132 70
154 80
8
90,000L
100,000L
lbs
kg
lbs
kg
176
90
198 100
353 180
397 200
529 270
595 300
705 360
794 400
882 450
992 500 1,102
lbs
220
441
661
882

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis