Herunterladen Inhalt Inhalt Diese Seite drucken

Monitor & Maintain Your Ecosalt2 In-Line Cell - Davey EcoSalt 2 DES2-25EL Installations- Und Betriebsanweisungen

Chlorungssystem für salzbetriebene pools
Vorschau ausblenden Andere Handbücher für EcoSalt 2 DES2-25EL:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 33
IMPORTANT INFORMATION
ABOUT YOUR EcoSalt2
FACTORS THAT WILL IMPROVE THE PERFORMANCE & LIFE OF YOUR EcoSalt2.
PLEASE READ THIS BEFORE OPERATING YOUR CHLORINATOR
POOL BUILDERS:
Please cover this information with your customer during the new pool "Handover Session".
Chlorinators are a valuable piece of pool equipment and must be cared for to get the best
performance and life span. There are THREE main factors that will damage your EcoSalt2
and reduce the life of the product. Please monitor the following factors in accordance with your
installation & operating instructions.
1. MAINTAIN RECOMMENDED SALT LEVELS
RECOMMENDED OPERATING RANGE: (see page 27)
• Run your EcoSalt2 at the salt levels stated within this document and on the product to
ensure optimum performance and cell life;
• Operating the EcoSalt2 at low salt levels will damage the cell and reduce its life;
• The control panel displays a flashing red LED indicator warning when the salt levels
are low;
• If no action is taken to rectify the salt levels, damage to the cell may result which will
not be covered under warranty.
2. MONITOR & MAINTAIN YOUR EcoSalt2 IN-LINE CELL
EcoSalt2 has a "reverse polarity" in-line cell.
• To keep your EcoSalt2 in the best possible condition, regular monitoring of the cell is
recommended. The cell is in the clear plastic housing and contains the Titanium plates.
• During the chlorination process a white powdery Calcium scale may naturally build up
on the Titanium plates in the cell. Monitor the cell to prevent excessive scale build up.
Excessive scale build-up will cause damage to your cell, and dramatically reduce its
efficiency and lifespan.
• The control panel displays a red LED indicator warning that indicates that the cell may
require cleaning.
• If Calcium scale builds up please clean the cell, following the cleaning instructions provided
on page 26.
• NEVER: Use concentrated acid to clean your cell.
• NEVER: Leave cell in cleaning solution for extended periods of time.
• NEVER: Use metal implements, scourers, or brushes to clean the cell.
3. BALANCED POOL WATER CHEMISTRY
• Correct salt levels MUST be maintained (see page 27) for optimum performance and lifespan.
• Calcium Hardness levels MUST be kept to ideal ranges of 200 - 275ppm (for Concrete
and Tiled Pools) and 100 - 225ppm (for other surfaces) to prevent excessive scale build up
and damage to equipment.
• pH levels MUST be kept to ideal levels to prevent damage to equipment and pool surfaces
and to obtain optimum chlorination effectiveness.
• Total Alkalinity and Stabiliser levels must also be kept in an ideal range.
Note: Please refer to the POOL WATER CHEMISTRY chart on page 29 for more information.
5

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis