Once the salt concentration is corrected, the LOW SALT CUT-OUT ALARM must be reset by pushing the
manual ON/OFF button. Alternatively, the EcoSalt2 will conduct a system check automatically when
powered up the next time (if operating via a separate power supply). Upon start-up if the EcoSalt2 registers
a salt concentration within range (refer to recommended salt range section in the manual), the EcoSalt2 will
return to normal operation.
LOW SALT CUT-OUT ALARM is triggered at the following (approximate) salt concentrations:
EcoSalt2 model
DES2-15EL, DES2-25EL
DES2-15E, DES2-25E, DES2-35E
ADD SALT ALARM AND LOW FLOW ALARM
Should the EcoSalt2 register low flow and a salt concentration below its minimum (refer to recommended
salt range section in the manual), the EcoSalt2 will alarm. The display will toggle between the ADD SALT
ALARM and the LOW FLOW ALARM. In LOW FLOW ALARM, the EcoSalt2 will not produce chlorine. As
shown previously once faults are rectified, normal operation will resume.
OVERRIDING LANGUAGE SETTING
> From the HOME screen, press and hold
menu up/down buttons to scroll down to LANGUAGE;
> Press the
> Adjust language following instructions detailed in INITIAL START UP section, earlier in this manual.
Low salt cut-out alarm (approx. salt concentration)
1,200ppm
2,500ppm
70% – 09:35 AM
CHLORINE OUTPUT
menu/setting select for 3 seconds.