Herunterladen Inhalt Inhalt Diese Seite drucken

AFRISO WGA 01 Anleitung Seite 13

Öl-, benzin- und fettdetektor
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Declaration thermistor probe R6
The above name product is considered to be "simple apparatous" according to the
ATEX directive (2014/34/EU). The ATEX directive is not applicable to simple
components that consists of well defined and simple semiconductor devices.
The probes design is verified according to the requirements of the ATEX-directive
EN 60079-0:2012
EN 60079-11:2012
Intrinsically Safe Design : II 1 G Ex ia IIB T3
Electrical Parameters :
Operating temperature :
Conditions for use :
Signed:
Urban Nilsson
Position:
Technical Manager
Datum:
2016-06-10
Afriso Ema AB, Kilvägen 2, SE-232 37 Arlöv, Sweden, www.afriso.se
Declaration of conformity
Thermistor probe type R6
Equipments - General requirements
Explosive atmospheres - Equipments protected by
intrinsic safety "i"
Ci: 1 nF, Li: 10 uH, Ii: 200 mA
Ui: 30,0 V, Pi: 1,25 W
-25 to +50° C
Must be connected to a barrier isolated from earth.
With electrical parameters not exceeding the maximum
value of the intrinsically safe output parameters of the
connected barrier.