2. Remove the top 5/16'' bolts and the lower ¼'' bolts
(D) from the 2 sides of the frame. Do not discard the
bolts.
3. Loosen but do not remove the lower 5/16'' bolts (C)
on the 2 sides of the frame.
4. Remove the auger belt (B) from the engine pulley
(A).
5. Tilt the rear section down. The front section tilts
forward at the same time. The bottom bolt is a hinge
between the front and rear sections.
6. Put a wooden block below the hinge point to set the
product in the tilted position.
7. Move the auger brake arm and remove the auger
belt (B) from around the auger brake arm.
To remove the auger belt (for ST 424T/
427T/430T only)
1. Remove the 5/16'' nut and the cable cover (E) from
the frame. (Fig. 80 )
2. Remove the top 5/16'' bolts from the 2 sides of the
frame. Do not discard the bolts.
3. Remove the lower 5/16'' bolts (C) on the 2 sides of
the frame.
4. Remove the auger belt (B) from the engine pulley
(A).
5. Use the adjustment lever for the auger bucket to tilt
the rear section down. The front section tilts forward
at the same time. The bottom bolt is a hinge
between the front and rear sections.
6. Put a wooden block below the hinge point to set the
product in the tilted position.
7. Move the auger brake arm and remove the auger
belt (B) from around the auger brake arm.
To install the auger belt
1. Move the auger brake arm (G). Put the auger belt
around and in the groove of the auger pulley (E).
(Fig. 81 )
CAUTION: Make sure that the belt is not
caught between the frame and auger
housing as you put the unit together.
2. Remove the wooden block from below the product.
3. Lift the handles to tilt the rear section up. The front
section tilts back and pivots to attach to the rear
section.
4. Make sure that the belt is put in the auger pulley (E)
groove correctly.
5. Install the 5/16'' bolts (C), and tighten (11-16 Nm).
6. For ST 424/427/430 only: Install the ¼'' bolts (D) and
tighten (5-8 Nm).
7. Install the auger belt (B) on the engine pulley (A).
Make sure that the belt is put correctly around the
idler pulley and installed correctly in the engine
pulley groove.
22
8. Install the cable cover (F) and the 5/16" nut on the
frame.
9. Operate all controls to make sure that the auger belt
is installed correctly and that all components are
moving correctly.
To adjust the auger belt tension
Note: An assistant is necessary to do this task.
1. Remove the belt cover. See
replacement of the belts on page 21 .
2. Loosen the idler pulley nut (A).(Fig. 82 )
3. Move the idler pulley (B) in the direction of the auger
belt to increase the belt tension. Move it away from
the auger belt to decrease the belt tension.
4. Tighten the idler pulley nut (A).
5. Have the assistant stay 3 m (10 feet) in front of the
product to monitor the movement of the auger.
6. Push and then release the auger engagement to
start and stop the auger.
7. Measure the time for the auger to stop moving. If the
auger stops after more than 5 seconds, release the
belt tension.
8. When the auger stops moving after less than 5
seconds, install the belt cover. See
cover on page 21 .
To adjust the auger control cable
1. Remove the cable cover on the right hand side of the
frame (D).(Fig. 83 )
2. To remove slack from the auger control cable,
unscrew the bottom jam nut (B) and tighten the top
jam nut (B) until the auger belt tension has
increased.
3. Retest the auger engagement. Repeat adjustment
as needed until only a small amount of slack remains
in the cable when the lever is disengaged.
4. Tighten the bottom jam nut to lock in the tension.
Note: You may also tension the auger belt by
adjusting the idler pulley as a secondary option. If
the adjustment does not resolve the problem,
replace the auger belt. See
on page 22 .
To adjust the release cable of the
discharge chute
1. To adjust the release cable, turn the cable adjuster
until the release lever of the discharge chute does
not move freely.(Fig. 84 )
To adjust the left and right discharge
chute cables
1. Put the discharge chute lever in the center position.
To prepare for
To install the belt
To install the auger belt
891 - 002 -