Safety Notes

Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal
pressures.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• 71860000: If the instantaneous water heater
causes problems or if you wish to increase the water
flow, the EcoSmart
aerator can be removed.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
The product is exclusively designed for drinking water!

Symbol description

Do not use silicone containing acetic acid!
Adjustment (see page 34)
To adjust the hot water limiter. Using a hot water limiter
in combination with a continuous flow water heater is
not recommended.
Fault
Mixer stiff
Mixer dripping
Water escaping in area of swivel
spout
Water escaping at the threaded
base
Hot water temperature too low
4
(flow limiter) located behind the
®
max. 1 MPa
0,1 - 0,5 MPa
(1 MPa = 10 bar = 147 PSI)
max. 70°C / 4 min
Cause
- Cartridge defective, calcified
- Cartridge defective
- O-ring defective
- O-ring at the connection hose de-
fective.
- Hot water limiter incorrectly set
Assembly (see page 32)
English
• Hansgrohe recommends not to use as drinking water
the first half liter of water drawn in the morning or
after a prolonged period of non-use.
• After periods of prolonged non-use, but at least
every third day, the fittings must be opened with the
handle in hot and cold position to prevent stagnation
in the connecting lines. Let the water run until the
water temperature is constant.
1,6 MPa
max. 70°C
65°C
Dimensions (see page 37)
Flow diagram (see page 37)
with EcoSmart
®
without EcoSmart
®
Spare parts (see page 41)
Cleaning (see page 40)
Operation (see page 35)
Test certificate (see page 48)
Remedy
- Exchange cartridge
- Exchange cartridge
- Exchange O-ring
- Exchange O-ring
- Set hot water limiter