7. Disposal

Packaging
The packaging material is 100 % recyclable.
Observe local disposal regulations. Keep the packaging material out of the reach of children, since it
represents a potential source of danger.
Product
The product is made from recyclable materials.
This device has the conformity marking in accordance with
the European Directive 2002/96/EC, Waste Electrical and
Electronic Equipment (WEEE).
Risks to the environment and health can be ruled out if the device is properly disposed of by
the user. The symbol on the device indicates that this device is not to be treated as household
waste, but is to be handed in to special collection and recycling points for waste electrical and electronic
equipment. Before disposal, remove the power supply cable. The national regulations on the disposal of
electrical equipment must be complied with.
For more information on the treatment, recovery and recycling of this product, please contact the relevant
local authority, refuse collection point or the dealer from whom the product was purchased.

8. Troubleshooting

Error
Water is not dispensed
Not enough water is
dispensed
Cold water cannot be
dispensed
Cannot dispense CO2
26
Cause
Not enough water
pressure in the water
supply
Filter cartridge is blocked
Problem with the pressure
regulation or the pump in
the device
Not connected to the
power supply
Filter cartridge is blocked
Incoming water pressure
too low
On/off switch for cooling
(COLD) is off
No coolant available
Problem with the
thermostat or compressor
No water in the cold water
supply
Ice formation in the cold
water tank
Not enough water in the
tank
Defective pump
CO2 On/off switch on the
rear panel is switched off
Error recovery
Increase the water pressure
Insert new filter
Contact a service technician
Connect the device to the power supply
Insert new filter
Check and, if necessary, increase incoming water
pressure
Switch on the On/off switch for the cooler (COLD) on
the rear panel
Contact a service technician
Contact a service technician
Check the water supply.
If this is in working order, inspect the water pipework
in the device
Disconnect the device from the power supply, allow
the ice to melt, reconnect the device to the power
supply or switch it off
Top up the water or refill the tank and check the
device's pipework.
Contact a service technician
Switch the CO 2 On/off switch to On

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis